Bellows-Type Orifice Meters 
								
								Author(s): Giles m. Crabtree 
								
Abstract/Introduction:
								The bellows-type d i f f e r e n t i a l gauge has found widespread application and increasing popul a r i t y in o r i f i c e metering. Its operation does not require mercury nor c r i t i c a l leveling for operation. The rapid response and high output torque make the bellows meter p a r t i c u l a r l y adaptable to integrating and c o n t r o l l i n g devices. The meter is generally not affected by condensed l i q u i d in the measuring system. The s e l f - d r a i n ing feature along with proper i n s t a l l a t i o n makes it very adaptable to wet gas measurement.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									58EBDDAB
								
								
							
								
								
							
								
									Diaphragm Meter Capacity Ratings At Elevated Pressures 
								
								Author(s): Howard W. Berghegger 
								
Abstract/Introduction:
								Diaphragm displacement meter cases or bodies are manufactured of various materials to accommodate their application and metering pressures which range from a few inches of water column to several hundred psig.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									0AB1FFAC
								
								
							
								
								
							
								
									Operation And Maintenance Of Catalytic Heaters
								
								Author(s): Morris Sadleir 
								
Abstract/Introduction:
								Catalytic Heaters convert natural gas or LPG into a safe, flameless, radiant heat. This conversion is accomplished through a catalytic reaction in which natural gas (or LPG) and oxygen are brought into contact with a catalyst at minimum temperature of 225 F . Merriam-Webster defines a catalyst as a substance or agent inducing catalysis a substance that initiates a chemical reaction and enables it to proceed under milder conditions than otherwise possible. Extensive research on the effectiveness of catalysts in promoting the reaction of combustible gases with oxygen or air has established platinum as a desirable catalyst for use in flameless catalytic gas heaters
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									B5BF6555
								
								
							
								
								
							
								
									Determination Of Plant Volume Reduction
								
								Author(s): H. C. Tilley 
								
Abstract/Introduction:
								Plant Volume Reduction Is the reduction in gas volume between the volumes of gas delivered from all sources for processing in the plant and tie volume of residue gas resulting from the removal of liquid and liqueflable hydrocarbons, shrinkage, lant fuel usage, flaring, compressor fuel and other uses or losses of gas in the plant incident to or occasioned by processing gas.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									D03D51BC
								
								
							
								
								
							
								
									The Use Of Manometers In The Gas Industry
								
								Author(s): Nick Gestrtch 
								
Abstract/Introduction:
								SIGNIFICANCE In the Measurement Mans Corner of Gas Magazine in April, 1967, it was stated, If the gas measuremimt science could be represented by a corpse, upon dissection the heart would turn out to be a manometer,
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									D8044BD8
								
								
							
								
								
							
								
									Charts, Pens, And Inks 
								
								Author(s): Wl Iam L. Tatarski 
								
Abstract/Introduction:
								Most people involved in Gas Measurement are familiar with instrumentation and how they are used to collect and transmit data, and many claim to be familiar with charts, pens, and inks, but how many really know the total relationship between these three elements.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									2F08CB2A
								
								
							
								
								
							
								
									Metrication 
								
								Author(s): D. Spence 
								
Abstract/Introduction:
								Conversion to SI is now largely an accomplished fact in the Canadian Gas Industry and this paper is a resume of how it was accomplished in a gas utility with particular emphasis on gas measurement.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									255CCC44
								
								
							
								
								
							
								
									Principles, Application And Sizing Of Monitor Regulators 
								
								Author(s): Donald A. Jones 
								
Abstract/Introduction:
								Monitor regulation as an overpressure safety device has been around for many years. However, since the Department of Transportation, Office of Pipeline Safety was given the authority to prescribe and enforce safety standards back in 1968, the use of monitor regulators has increased dramatically throughout the natural gas industry.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									F5C7673D
								
								
							
								
								
							
								
									Methods Of Field Testing Large Capacity Meters 
								
								Author(s): A Panel, R. m. Nicholson 
								
Abstract/Introduction:
								The information presented in this paper is a resume of the various methods of field testing large capacity meters. The methods we will cover are: Low pressure flow proving, which is the use of an orifice meter at low pressure to compare the meter to. Critical flow proving, which tests the meter at its operating pressure by comparing it to the flow through a critical flow nozzle. Transfer testing , which is comparing the meter to another meter that is an accurate standard. Differential pressure testing of rotary meters, which is checking the condition of a rotary meter by the differential necessary to operate it. Spin testing is used with turbine meters to check the condition of the meter by timing the length of spin of the roto
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									6B4AEF01
								
								
							
								
								
							
								
									Methods Of Field Testing Large Displacement Meters 
								
								Author(s): Jim Juckes 
								
Abstract/Introduction:
								The reasons for con measurement &re obv to larger meters is our towns one or a revenue than severa My mission here is ing the I n t e g r i t y o placement meters th WHY FIELD TEST? s t a n t l y seeking accurate gas ious. The extra attention given s t r i c t l y economic. In many of few large customers provide more 1 thousand residential customers to suggest methods for maintainf measurement with large d i s - rough proper f i e l d t e s t i n g.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									60C8374A
								
								
							
								
								
							
								
									Test Instruments For Pressure And Water Vapor 
								
								Author(s): A. W. Chandler 
								
Abstract/Introduction:
								Volume measurement of natural gas at high pressure is principally accomplished by means of orifice type flow meters. Converting orifice meter readings to low pressure volumes requires exact knowledge of pressure and supercompressibility.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									12F7FE71
								
								
							
								
								
							
								
									LILA.KAGE And Unaccounted-For Gas
								
								Author(s): J. H. Coyle 
								
Abstract/Introduction:
								The unaccounted-for gas is the difference between the amount of gas received into a pipeline system and the amount of gas delivered out of a pipeline system over a given time period. Unaccounted-for gas in a system is very costly and deserves the attention of both the office and field personnel alike.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									144C672A
								
								
							
								
								
							
								
									Meter Shop Design, Equipment And Techniques 
								
								Author(s): Jim Jukes 
								
Abstract/Introduction:
								The gas meter repair shop has graduated - it is no longer a back yard nuisance created to satisfy state requirements. If awareness pervades the executive suite, reliable measurement probably ranks second only to rates, conservation and supply. A glance at your own gas bill should supply the evidence.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									5C871B6D
								
								
							
								
								
							
								
									Manual Procedures For Chart Calculation 
								
								Author(s): William N. Donachy 
								
Abstract/Introduction:
								Chart Departments of a natural gas company deal with the calculation of volumes of gas. Whether or not gas is exchanged, purchased, sold, transferred front one system to another, or used in company operaition, the procedures for calculation of charts are normally designed to actually ac:count for the quantity of gas represented by the chart record.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									027C6B04
								
								
							
								
								
							
								
									Test Instruments And Recorders For Specific Gravity 
								
								Author(s): A. R. Kahmann 
								
Abstract/Introduction:
								Computation of natural gas flow volume, when measured by orifice meter, is made by using the formula
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									A7914824
								
								
							
								
								
							
								
									Freeze-Up Preventations
								
								Author(s): Michael P. Hogan 
								
Abstract/Introduction:
								Gas ureeze-ups are a problem that plague the gas industry all the way from the production fields, through the transmission system, in to the distribution system and on through the individual customers meter. Improper treatment of this problem can potentially cause major interruption to large numbers of customers due to ice blockage or possible overpressuring of distribution systems due to freeze-ups in pressure reducing facilities-
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									49846B13
								
								
							
								
								
							
								
									Turbulence And Itei Effects In Measuring S Regulating Staticms 
								
								Author(s): Robert H. Walker 
								
Abstract/Introduction:
								WHAT IS THE REASON FOR A REGULATOR STATION BEING A POTENTIAL SOURCE OF UNDESIRABLE NOISE?
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									6EFD7000
								
								
							
								
								
							
								
									Calibration Of Storage Tanks
								
								Author(s): F. R. Conway 
								
Abstract/Introduction:
								Tank Calibration is commonly referred to as Tank Strapping. Tank strapping was originally the work of placing metal straps around wooden containers this was generally before the Petroleum Industry came into being. The wooden containers most commonly used were for liquor or Whale Oil.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									C62A56E6
								
								
							
								
								
							
								
									Stealing Gas A Growing Problem
								
								Author(s): Raymond G. Fcremer 
								
Abstract/Introduction:
								Is stealing gas or in fact all forms of energy an increasing or perhaps even more accurately, a national problem? You can quickly draw your own conclusions by simply reading the nev/spapers, Cleveland Ohio newspapers reported a loss of 3.2 million dollars by the Cleveland Electric Illuminating Co. and put the East Ohio Gas Companys loss at 10 of its net profit. Similarly Chicago Illinois papers noted E 7 million dollar loss for Commonwealth Edison, with the Peoples Gas Light and Coke Co. sJid Northern Illinois Gas Co. indicated as jointly having a loss of similar magnitude. The Miami Herald has reported on similar problems experienced by Florida Power and Light. New Orleans Public Service, Public Service Electric and Gas (New Jersey), Long Island Lighting, Con Ed, and my own company Brooklyn Union Gas are among the names on a long list of companies that have experienced significant meter tampering problems.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									705C22AB
								
								
							
								
								
							
								
									Domestic Meters
								
								Author(s): Thomas J. Smith 
								
Abstract/Introduction:
								The definition of a domestic meter is a meter having a capacity of 500 CFH or less. CONSTRUCTION Formerly these units were offered in a variety of case materials. Probably the most common of these were tinned steelcase commonly referred to as Tin Meters. These low pressure, handmade meters are accurate, the high cost of manufacture and repair, pressure limitations, lack of corrosion resistance and susceptibility to pipe stress made these units obsolet
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									5C9A83B4
								
								
							
								
								
							
								
									Use Of Video Tape In A Measurement Department 
								
								Author(s): J. U. Sutton 
								
Abstract/Introduction:
								Most companies expect their Measurement Technicians to be proficient at installing and maintaining regulators, controllers, dehydrators, samplers, telemetering equipment, etc. Providing the technician with j ust the f ondaihental information required to perform these tasks is a never ending problem for those responsible for training. Remember training alone can never be substituted entirely for experience.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									FA872E2E
								
								
							
								
								
							
								
									Instrument Calibration Using The Pneumatic Deadweight Tester 
								
								Author(s): Bob Pitre 
								
Abstract/Introduction:
								The pneumatic deadweight tester was developed 25 years ago for calibration of low pressure instruments. Through the years the tester has undergone many refinements that have increased its range capabilities. Pneumatic testers are now capable of calibrating instruments that range from 4 inches of water pressure to 1000 PSIG. For demonstration purposes, a pneumatic tester with an output pressure calibrated in inches of water will be later used to show how the pneumatic tester is used in instrument calibration.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									5F51FB4C
								
								
							
								
								
							
								
									Effects And Control Of Pulsations In Gas Measurement
								
								Author(s): Wa.ter W. Von 
								
Abstract/Introduction:
								Pulsations have detrimental effects on the .accuracy of gas flow measurement. Consequently, effective pulsation control in meter runs is needed to minimize flow measurement uncertainty due to pulsations. This paper discusses techniques available for pulsation control and Illustrates the application of such techniques to several gas gathering systems.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									BF102394
								
								
							
								
								
							
								
									Large Capacity Displacement Gas Meters
								
								Author(s): John L. Esola 
								
Abstract/Introduction:
								The term Large Capacity Displacement Meters, as used by the gas distribution industry, refers to those diaphragm type meters with a capacity of 500 to 10 or 11,000 cfh of 0.64 specific gravity natural gas at a maximum of 4 ounces inlet pressure with no more than two inches water column differential pressure between the meter inlet and outlet at capacity flow. It also refers to rotary meters which also operate on the positive displacement principle.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									5CED1513
								
								
							
								
								
							
								
									Instaliation, Operation And Maintenance Of Automatic Chart Changers
								
								Author(s): Bruce Caldwell 
								
Abstract/Introduction:
								Automatic chart changers were developed for the specific purpose of changing circular charts at fixed time intervals, consistent with each 360 of chart rotation. This is accomplished by having a supply of standard charts stored on a chart plate which will release the topmost chart at a predetermined time periods
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									20128472
								
								
							
								
								
							
								
									Leak Detection On Petroleum Pipelines 
								
								Author(s): Terry P. Lindsey, James C. Vanelli 
								
Abstract/Introduction:
								The advent of sophisticated computer-based pipeline control and data acquisition systems has made possible significant improvements in real-time leak detection. As a result, pipeline surveillance has reached accuracies which not only allow identification of leaks, but provide excellent integrity checks on flow measurement. The discussion to follow will suggest a general approach to achieving an accurate line surveillance system and present test data in support of some of the various methods to be mentioned.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									1942B1E3
								
								
							
								
								
							
								
									Advanced Applications Of Flow Computers And Telemetering 
								
								Author(s): Thomas R. Tolbcrt 
								
Abstract/Introduction:
								As the price of natural gas continues to climb, more effort is directed toward precise measurement of gas flow. Traditional gas flow measurement, by telemetering temperature, diliferential pressure and static pressure to a central gas dispatching office, has met with increasing demands for local computation of flow and flow totals (quantity), because of accuracy improvements over chart integration. Price alone is not the only factor involved. Loss of flow measurement during an equipment failure (central computer down), or more likely a temporary telemetry link problem.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									4AAFEA60
								
								
							
								
								
							
								
									Basic Applications Of Telemetering Systems & Flow Computers 
								
								Author(s): Robert F. Schwartz 
								
Abstract/Introduction:
								This paper will be a basic paper illustrating the various types of telemetering and flow computing systems as utilized in the Gas Industry. The paper will be general in nature, as the entire field of endeavor. Therefore, only basic fundamentals of the various types of flow computing and telemetering systems will be covered in this paper.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									A614D2C6
								
								
							
								
								
							
								
									New Developments In Rubber Plug Type Control Valves 
								
								Author(s): Robert H. Welker 
								
Abstract/Introduction:
								A control valve utilizing a solid rubber plug for the controlling mechanism was first introduced in the gas industry in 1958. Of particular importance to that industry is the fact that this is the only control valve used in the industry that was designed within the gas industry and specifically for gas service. Over the years field experience has influenced improvements in the rubber plug type valve that has broadened its scope of operation along with improving its operational reliability.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									77AB030B
								
								
							
								
								
							
								
									Gas Measurement By Rotary Meters 
								
								Author(s): Ben R. Wagner 
								
Abstract/Introduction:
								HISTORY The first positive displacement rotary gas meters were built around the year 1920 by the PH & FM Roots Company and the Connersville Blower Company, both located in Connersville, Indiana. In 1966 this gas meter operation was renamed Dresser Measurement Division. However, these rotary meters today are still known as ROOTS Meters
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									1F75F357
								
								
							
								
								
							
								
									Rotating Vane Gas Meters
								
								Author(s): Donald H. Knapp 
								
Abstract/Introduction:
								The use of Rotary Vane Meters has several distinct advantages over the use of bellows type positive displacement meters. Their relatively smaller size and weight provides a much more compact measuring package for the volumnes involved. This companys meter provides some additional important features. For example the interchangeable cartridge. This allows a previously calibrated cartridge to be exchanged in an existing body with no change in accuracy. The cartridge requires no periodic lubrication, is interchangeable with all working pressures and is not critical to level. Accuracy is maintained from 100% to 47, o the meters capacity: otherwise stated 25:1 range- ability.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									D2C0BDF2
								
								
							
								
								
							
								
									Fundamentals Of Gas Turbine Meters 
								
								Author(s): William N. Donachy 
								
Abstract/Introduction:
								The gas turbine meter has become firmly entrenched as a measurement tool in our industry over the past fifteen years. This paper will present operating principles, construction, application and testing of the gas turbine meter
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									BD773C63
								
								
							
								
								
							
								
									Large Volume Measurement By Turbine And Rotary Meters 
								
								Author(s): Daniel R. Fulton 
								
Abstract/Introduction:
								Volume measurement of gas by turbine and rotary type gas meters is becoming increasingly Important. Each type meter has its own characteristics and each offers distinct advantages in the production, transmission and distribution segments of the gas industry. With the value of gas increasing significantly, more attention is being given to accurate measurement at the point of sale and quite often, depending on the flow rates, either turbine or rotary meters best fit the need. For instance, in production measurement the turbine and rotary meter are used in custody transfer, well testing, compressor fuel and in other field accounting applications. In the transmission segment these same meters are used for custody transfer of gas volumes as well as for internal accounting of gas usage such as compressor fuel consumption. In distribution measurement turbine and rotary meters are used for large volume sales to industrial and commercial type accounts.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									8D41917D
								
								
							
								
								
							
								
									Field Experience With Turbine Meters 
								
								Author(s): Chalmus E. Allen 
								
Abstract/Introduction:
								Ten years ago the gas turbine meter was virtually unknown in the gas transmission industry. Its use was limited to a few companies who were doing more experimenting and testing than buying and selling with turbine meters. The majority of gas transmission companies would not accept it for custody transfer. Most producers were completely unfamiliar with the turbine meter and preferred more conventional forms of measurement.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									0ACBF598
								
								
							
								
								
							
								
									Gas Tukbihe Meters And Continuous Integrator
								
								Author(s): August Buchhalter, Jr. 
								
Abstract/Introduction:
								Since the introduction of the turbine meter to the U. S. gas industry in the early 60s, the turbine meter has found wide acceptance as a large volume measurement device.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									013EE3A1
								
								
							
								
								
							
								
									Installation, Operation And Maintenance Of Automatic Chart Changers 
								
								Author(s): Michael D. Beall 
								
Abstract/Introduction:
								Automatic Chart Changers were developed for the specific purpose of saving time and money by changing charts when there was no one present but by no means should they eliminate company meter technicians or their chart grabber personnel. These people will always be needed to check the calibration and performance of the meter as well as collect the charts, monitor them for any unusual record and forward them to the chart processing/accounting office at the end of the month.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									FC2850E1
								
								
							
								
								
							
								
									Orifice Fittings And Meter Tubes 
								
								Author(s): Ed Prlngle 
								
Abstract/Introduction:
								Due to the continually increasing cost of hydrocarbon products, both liquid and gas, there is a growing concern for accurate measurement. In many applications this begins with a signal from the primary element, consisting of the Orifice Fitting, Orifice Plate and Meter Tube.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									B4768658
								
								
							
								
								
							
								
									Installaticw, Operaticn And Maintenance Qp Automatic Chart Changer
								
								Author(s): John H. Lindsey 
								
Abstract/Introduction:
								INTPODUCnCN Autcmatic Chart Changers have proven time and tine again that they will save noney for operating ccmpanies ien used judiciously.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									B93BADFD
								
								
							
								
								
							
								
									Selection, Testing, Maintenance And Operation Of Electronic Flow Computers
								
								Author(s): Adam R, Durant 
								
Abstract/Introduction:
								Today as we read headlines such as Energy Reserves are Lou and Energy is Running Out, we can also see the price of energy going through the ceiling. With this, one can realize why the accuracy of measuring energy and the ability to obtain fast and up-to-date records is becoming very important. Until recently the orifice meter with mechanical chart recorder has been used to obtain this information, but this was a slow and timely procedure and was not as quickly up-dated as was needed. This need for information is needed not only for billing, but for almost every aspect of business, such as fast and reliable controlling, and the planning and prospects of new and added features of our systems. All of these reasons and more have led to the electronic flow computer becoming an important part of the energy industry today.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									F7AF37CD
								
								
							
								
								
							
								
									Electronic Chart Scahnihg And Related Equipment 
								
								Author(s): R. E. Randall 
								
Abstract/Introduction:
								The first Electroscanner was introduced in 1961. This first version had a digital computer and two scan stations. The computer was changed later to an analog version and in 1970 further improvements including integrated circuits and additional optional circuitry were added. All of these improvements have greatly reduced the cost and increased the accuracy and reliability of the instrument.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									8048AFA6
								
								
							
								
								
							
								
									Maintaining An Electroscanner And An Analyzer 
								
								Author(s): Thomas Y. Tramel 
								
Abstract/Introduction:
								A short time after integrated circuits were available to the industrial market, we at UGCl redesigned our proven Electroscanner. Incorporating integrated circuits into our computer, in addition to other changes, has made possible a much more accurate and reliable Electroscanner system. This change in computing circuitry also eliminated much of the maintenance necessary to keep the Electroscanner functioning properly.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									9FEB6336
								
								
							
								
								
							
								
									Elements Of Cas Contracts 
								
								Author(s): James E. Sirois 
								
Abstract/Introduction:
								This paper will review the elements of pas contracts as seen through the eyes of a Gas Buyer for an interstate pipeline. There are certain variations between interstate and intrastate gas contracts as well as certain differences between the contracts of different interstate gas pipelines. Regardless of these differences, certain basic subject matter must be addressed in all gas contracts.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									8AFB215A
								
								
							
								
								
							
								
									Operation Of Orifice Meter Chart Integrators
								
								Author(s): Marl In E. Smith 
								
Abstract/Introduction:
								Measurement by Orifice Meter has been developed to be the simplest and most accurate device for measurement of large volumes of gas. Since that time we have been seeking better ways to interpret the Orifice Metpr Charts, First we simply used the Sight Reading Method. This method we averaged the static and differential separately and multiplying the results together, Then came along the Planimeter Method. We rotated the chart manually under a pen arm and the product of static and differential pressures were obtained separately. Both of these methods were good when the flow was constant, however they provide the square root and not the average square root, which is the desired results
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									F8EDE62E
								
								
							
								
								
							
								
									Determination Of Lkakage And Unaccounted-For Gas - Distributiok
								
								Author(s): Scott C. Smith 
								
Abstract/Introduction:
								The term Unaccounted-for gas has been described as being the difference between the amount of gas purchased and the amount sold. Expressed in percent it would be (Gas Purchased - Gas Sold) Gas Purchased X 100. However, one set of figures is never enough. One must not only have the figures in MCF lost (or gained), but also the percentage, MCE/mile of 3 equialent, and most importantly the trends in all of these figures. Discussed herein are some possible causes of unaccounted-for.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									F994CB0E
								
								
							
								
								
							
								
									Instruments For Leakage Detection 
								
								Author(s): David E. Bull 
								
Abstract/Introduction:
								Key factors involved in selecting the proper instrument for the detection of combustible gases involves several decisions. These include definition of problem areas, economic limitations, a review of principles to be used and the choice of the best Instrumentation available. We must engineer, supervise and check out the instrument installation. Supervision of the use of the equipment must Include the training of all personnel in their respective areas. Equally important is the establishment of routine maintenance and calibration schedules including the maintenance of a written log on these schedules. Attention to establishing the guidelines noted above will prepare us to better meet our industry safety objectives and at the same time help us to comply with state and federal codes.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									8E8BDF7E
								
								
							
								
								
							
								
									Accounting For Unaccounted-For Gas 
								
								Author(s): W.B. Richardson, III 
								
Abstract/Introduction:
								THE INCREASING COST OF NATURAL GAS HAS MADE IT MOST IMPORTANT TO HAVE AS FEW LOSSES AS POSSIBLE IN A PIPING SYSTEM. GAS THAT IS PURCHASED BUT NOT SOLD IS A MONEY LOSS TO A GAS COMPANY. MORE THAN EVER IT IS NECESSARY TO KEEP RECORDS OF UNACCOUNTED FOR GAS, TO DETERMINE WHERE AND WHY IT OCCURS, AND TO CORRECT AS MUCH OF THE PROBLEM AS IS PRACTICAL.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									609B4FE6
								
								
							
								
								
							
								
									Odorization 
								
								Author(s): J. Ronald Pope 
								
Abstract/Introduction:
								NATURAL GAS, AS IT IS OBTAINED FROM GAS WELLS, IS BOTH ODORLESS AND COLORLESS. IT IS COMPOSED PRIMARILY OF METHANE, BUT IT ALSO CONTAINS SMALL AMOUNTS OF ETHANE, PROPANE, AND OTHER HEAVIER HYDROCARBONS. ALTHOUGH THESE HEAVIER HYDROCARBONS HAVE A FAINT SWEETISH SMELL, NATURAL GAS AS A WHOLE HAS NO ODOR DUE TO ITS LARGE CONTENT OF METHANE, WHICH IS ODORLESS.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									D233974B
								
								
							
								
								
							
								
									Sonic Nozzles For Gas Meter Calibration
								
								Author(s): J.T. Jones 
								
Abstract/Introduction:
								IT HAS LONG BEEN EVIDENT THAT A CALIBRATION STANDARD HAS BEEN NEEDED FOR DETERMINING THE ACCURACY OF HIGH PRESSURE, LARGE VOLUME METERING DEVICES. WITH THE GROWING ACCEPTANCE OF THE TURBINE METER AS A CUSTODY TRANSFER METERING DEVICE, THIS NEED HAS BECOME INCREASINGLY GREATER.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									DB585757
								
								
							
								
								
							
								
									New Ideas In Gas Measurement And Pressure Regulation 
								
								Author(s): Richard A. Price 
								
Abstract/Introduction:
								WHATS NEW? THIS QUESTION IS ASKED THE MEASUREMENT AND REGULATOR MECHANIC ALMOST DAILY.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									CD6A67B3
								
								
							
								
								
							
								
									High Pressure Measured And Regulating Station 
								
								Author(s): William H. Ryan 
								
Abstract/Introduction:
								FROM THE LARGE CITY GATE, WHICH PASSES SEVERAL MILLION CUBIC FEET PER DAY TO THE FARM TAP,WHICH PASSES BUT A FEW MCF PER MONTH, SAFE OPPERATION, ACCURATE MEASUREMENT AND DEPENDABLE REGULATION, ARE THE PRIMARY GOALS OF ANY DESIGN FOR A HIGH PRESSURE MEASURING AND REGULATING STATION.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									3073A932
								
								
							
								
								
							
								
									Skid Mounted Meter And Regulator Stations. 
								
								Author(s): Bruce Shrake 
								
Abstract/Introduction:
								WHEN DESIGNING SKID MOUNTED METER AND REGULATOR STATIONS, THE DESING CRITERIA SHOULD MEET THE FOLLOWING OBJECTIVES: ACCURATE MEASUREMENT, SAFETY, MINIMIZE FIELD START UP COSTS, COMPACT YET FLEXIBLE FOR FUTURE EXPANSION, AND ACCESSIBILITY.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									6D57D89F
								
								
							
								
								
							
								
									Expansible Element Valves For Pressure Regulation And Relief 
								
								Author(s): Fred Loring 
								
Abstract/Introduction:
								EXPANSIBLE ELEMENT VALVES, ALSO KNOWN AS SLEEVE-TYPE VALVES, HAVE BEEN SERVING THE NATURAL GAS INDUSTRY FOR MORE THAN THIRTY YEARS. THEY ARE COMMONLY USED FOR PRESSURE REGULATION, OVERPRESSURE PROTECTION, AND FLOW CONTROL. MODERN DESIGNS HAVE GREATLY REDUCED SIZE AND WEIGHT, AND MAINTENANCE IS EASILY ACCOMPLISHED WITH BUT FEW COMMON TOOLS. IN THIS PAPER WE SHALL EXAMINE THE CONSTRUCTION, OPERATION, APPLICATION AND MAINTENANCE OF ONE OF THE EXPANSIBLE ELEMENT VALVES, THE AXIAL FLOW VALVE.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									85CC975E
								
								
							
								
								
							
								
									Domestic Gas Service Regulators Operation, Selection, Installation And Methods Used For Shop Repair 
								
								Author(s): Larry O. Boyle 
								
Abstract/Introduction:
								THE TERM, GAS SERVICE REGULATORS, COMMONLY APPLIES TO THOSE REGULATORS USED FOR REDUCING GAS PRESSURE IN POUNDS TO A REDUCED OR SERVICE PRESSURE OF FOUR TO EIGHT OUNCES AS REQUIRED BY DOMESTIC GAS BURNING EQUIPMENT, SUCH AS GAS STOVES, FLOOR FURNACES, HOT WATER HEATERS, CENTRAL HEATING, AND OTHER SIMILARGAS HEATING EQUIPMENT. SUCH GAS SERVICE REGULATORS ARE USED WHENEVER GAS PRESSURE IS DISTRIBUTED AT A PRESSURE IN POUNDS AND MUST BE REDUCED TO OUNCES PRESSURE FOR THESE APPLIANCES. THE REGULATOR IS INSTALLED AHEAD OF THE DOMESTIC METER BECAUSE THE METER IS DESIGNED TO MEASURE GAS CONSUMED ON THE PREMISES AT OUNCES PRESSURE AND NOT IN POUND PRESSURE.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									08CE0284
								
								
							
								
								
							
								
									Fundamental Principles Of Pilot Control 
								
								Author(s): Henry Hubbard 
								
Abstract/Introduction:
								PRESSURE REGULATORS USED IN THE FUEL GAS INDUSTRY ARE COMMONLY CLASSIFIED AS SELF-OPERATED OR PILOT-OPERATED. EACH TYPE HAS ADVANTAGES FOR CERTAIN APPLICATIONS. PILOT REGULATORS HAVE DISTINGUISHING CHARACTERISTICS, SUCH AS CONSTRUCTION, FUNCTION, OR OPERATION. GENERALLY THEY OFFER SUPERIOR PERFORMANCE IN APPLICATIONS INVOLVING HIGHLY VARYING FLOW CONDITIONS REQUIRING CLOSE CONTROL, AND WIDELY VARYING INLET PRESSURES AND HIGH RATES OF LOAD CHANGE.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									67DB2C5B
								
								
							
								
								
							
								
									Relief Valves - Design Am Calculations 
								
								Author(s): Phillip J. Murdock 
								
Abstract/Introduction:
								RELIEF VALVES ON NATURAL GAS TRANSMISSION AND DISTRIBUTION SYSTEMS ARE INSTALLED, IN A MAJORITY OF CASES, TO RELIEVE OVER-PRESSURE WHICH IS CREATED BY THE WIDE-OPEN FAILURE OF A REGULATOR. THIS TYPE OF INSTALLATION WILL BE USED TO ILLUSTRATE PRINCIPLES AND PROBLEMS INVOLVED IN RELIEF VALVE CALCULATIONS.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									B82BB286
								
								
							
								
								
							
								
									Application And Operation Of Ball Valve Regulators 
								
								Author(s): Roy J. Becker 
								
Abstract/Introduction:
								OVER TWENTY YEARS AGO A PLUG VALVE WAS EQUIPPED WITH A PNEUMATIC CYLINDER AND A POSITIONER AND USED AS A MONITOR REGULATOR. THE CONCEPT WAS A NEW METHOD OF GAS REGULATION AND WAS THE BEGINNING OF A NEW ERA.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									443A4523
								
								
							
								
								
							
								
									Operation And Maintenance Of Rubber Plug Type Control Valves 
								
								Author(s): Mack Jacobs 
								
Abstract/Introduction:
								AN URGENT NEED EXISTED FOR A GAS CONTROL VALVE THAT COULD MEET CERTAIN CRITERIA NOT AVAILABLE IN EXISTING VALVE DESIGNS, AND IN 1958 THE JET STREAM RUBBER PLUG TYPE CONTROL VALVE WAS INTRODUCED. BECAUSE OF THIS, SOME READERS WILL FIND THIS TO BE A REVIEW OF THINGS ALREADY KNOWN, WHILE OTHERS MAY DISCOVER A NEW VALVE.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									068C7EF8
								
								
							
								
								
							
								
									Fundamental Principles Of Orifice Meters 
								
								Author(s): Richard J. Golfer 
								
Abstract/Introduction:
								ORIFICE MEASUREMENT, THE DOMINANT METHOD USED IN THE GAS INDUSTRY TODAY, IS TRACEABLE EVEN TO THE ANCIENT ROMAN EMPIRE.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									B00E4022
								
								
							
								
								
							
								
									High Pressure Farm Taps And Service Regulators
								
								Author(s): Don Day 
								
Abstract/Introduction:
								HIGH PRESSURE FARM TAP REGULATORS AND THE LOW PRESSURE SERVICE REGULATOR ARE THE MOST BASIC AND NUMERICALLY THE MOST COMMON REGULATORS UTILIZED IN THE GAS INDUSTRY. THEY ARE SIMPLE, RELIABLE, LOW IN COST, EASY TO INSTALL AND REQUIRE PRACTICALLY NO MAINTENANCE - BOTH THE HIGH PRESSURE FARM TAP AND THE LOW PRESSURE SERVICE REGULATORS SHARE MANY SIMILAR CONSTRUCTION FEATURES SPRING AND DIAPHRAGM, BOOST EFFECT, SINGLE SOFT SEAT, MECHANICAL ADVANTAGE (LEVER ARM) BETWEEN VALVE AND DIAPHRAGM.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									FFF0AE0A
								
								
							
								
								
							
								
									Pressure Regulation And Flow Control With Expansive Tube Type Valves And Noise Abatement 
								
								Author(s): Dick Brunim 
								
Abstract/Introduction:
								SINCE 1948 WHEN IT WAS FIRST INTRODUCED TO THE GAS PIPELINE AND TRANSMISSION INDUSTRIES, THE EXPANSIVE VALVE HAS EARNED A REPUTATION FOR DEPENDABILITY AND VERSATILITY.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									86E66124
								
								
							
								
								
							
								
									Selection, Operation And Maintenance Of Regulators 
								
								Author(s): J.L. Esola 
								
Abstract/Introduction:
								EXTENDED TROUBLE FREE OPERATION OF A REGULATOR INSTALLATION CAN ONLY OCCUR IF INITIAL EQUIPMENT SELECTION IS PROPERLY MADE, AND THAT EQUIPMENT PROPERLY MAINTAINED.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									E70EE852
								
								
							
								
								
							
								
									Fundamental Principles Of Regulators 
								
								Author(s): A. Rea Cameron 
								
Abstract/Introduction:
								THE BASIC FUNCTION OF A REGULATOR IS TO CONTROL PRESSURE. THIS CONTROL IS PERFORMED BY REDUCING A HIGHER INLET PRESSURE TO A LOWER OUTLET PRESSURE AND MAINTAINING THIS OUTLET RESSURE CONSTANT OVER A WIDE VARIATION OF FLOW CONDITIONS.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									82ECB16D
								
								
							
								
								
							
								
									Large Capacity Gas Regclators 
								
								Author(s): J. K. Kruse 
								
Abstract/Introduction:
								The definition of a large capacity regulator is often difficult to formalize. There are many types of regulators which could be classified as large capacity. This discussion will be concerned with the conventional double ported regulator. The double ported balanced valve regulator is probably the most commonly used style of regulator labeled as large capacity. The large capacity is also often classified as high pressure due to the function of the restriction. The restricting element Is positioned by an operator to permit equal flow into and out of the downstream system, The capacity of a restrlctor Is a function of the pressure differential across that restriction, therefore, the higher the pressure differential across the restrlctor the greater the capacity for a given size restriction. The capacity will increase until sonic flow occurs. Sonic flow is the point at which the gas velocity reaches the speed of sound, and occurs when the outlet pressure absolute is approximately half the inlet pressure absolute.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									E0CD934E
								
								
							
								
								
							
								
									Industrial And District Regulators And Applications 
								
								Author(s): Frederick R. Loring 
								
Abstract/Introduction:
								Regulators employed In domestic service are generally used in standardized installations anc under somewhat similar operating conditions. In contrast to these, industrial regulators cover a bread spectrum of specialized applications with respect to pressure, flow capacity, accuracy, rangeability and other requirements. The multiplicity of available types provides an awesome choice to the uninitiated, but usually a few special requirements quickly narrow the selection for a given situation.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									EBB43835
								
								
							
								
								
							
								
									High And Low Pressure Regulators 
								
								Author(s): B. R. Llkins 
								
Abstract/Introduction:
								This topic covers a very broad area since it includes all Regulators used in the Gas Industry. Every Regulator is either High or Low Pressure depending upon the definition we use to classify them. Many Regulators can be both, again depending on the definition of High and Low Pressure.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									8E612684
								
								
							
								
								
							
								
									Gas Chromotography
								
								Author(s): Timothy J. Dunnigan 
								
Abstract/Introduction:
								Ch develop since 1 select i mixture colored column graphy. was est analyti chromat in fiel science romat ment 905. ve ab In comp and c In ablis cal t ograp ds as and ograp as an In t sorpt 1906 onent oined the hed a echni hlc t dive petro hy has be analytic hat year, ion to se Tswett s s in plan the word 1950s, c s a highl que. Tod echniques rse as th leum indu en in al technique Ramsey used parate a gas eparated the t s on a cbromotoh r o m a t o g r a p h y y sensitive ay various are in use e medical s t ry .
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									00B208CB
								
								
							
								
								
							
								
									Moisture Titrators
								
								Author(s): James C. Bozeman 
								
Abstract/Introduction:
								The prediction or actual determination of the amount of entrained moisture in natural, gas systems is recognized to be an essential part of pipeline operations. Water in the vaporous or fluid state poses not only operation probltms but also greatly aids in internal corrosion/ erroslon of the pipeline, the single largest investment most pipeline companies have, and it must be protected. By knowing the amount of moisture present, and where it is entering the system, various protective/preventive measures may be undertaken to negate the negative e:fects. In order to do this, the amount of moisture present as well as its source must be identified. This necessitates accurate means to measure the percentage of water to natural gas.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									322DC7AC
								
								
							
								
								
							
								
									Technical Session, Specific Gravity Instruments Installation And Operation 
								
								Author(s): E. F. Blanchard 
								
Abstract/Introduction:
								THE WHAT AND WHY OF SPECIFIC GRAVITY Fundamental to understanding specific gravity instruments and their use is the definition of specific gravity. Specific gravity is formally defined as the ratio of weight of a body to the weight of another body of equal volume taken as a standard unit. For gases, the standard is generally dry air. For example: Two tanks containing equal volumes of a gas and of dry air were weigned. After accounting for the weight of the containers, the dry air weighed one pound and the gas weighed 0.6 pounds. Using the definition of specific gravity:
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									D84A98C5
								
								
							
								
								
							
								
									Orifice Meters - Operation And Maintenance 
								
								Author(s): Lonnie R. Grady 
								
Abstract/Introduction:
								During the past few years, many new and advanced methods have been developed to measure natural gas. Each of these methods has its place in our industry, but the Orifice Meter has to be considered the standard and most widely accepted method of measurement. The purpose of this paper is to briefly discuss the operation and maintenance of Orifice Meters as used in the natural gas industry.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									854B51BE
								
								
							
								
								
							
								
									Kinetic Type Indicating And Recording Instruments For Determining Specific Gravity 
								
								Author(s): H. E. Lewis 
								
Abstract/Introduction:
								This class offers a comprehensive presentation of the kinetic type gas gravltometer. Including: Simple explanation of operating principle Equipment set-up and operation In field Trouble-shooting, repair and adjustment
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									DDFE5F84
								
								
							
								
								
							
								
									Specific Gravity Instruments - Care And Operation
								
								Author(s): L. W. Dunn 
								
Abstract/Introduction:
								THE ARCCO-AKUBIS GAS GRAVITOMETER This gravitometer is a direct weighing type instrument and Is constructed io measure the difference in the weight of a column of gas and an equal column oj dry air. This difference is transmitted to a chart on which is recorded the specifie gravity of the gas passing thru the instrument
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									12D7FAC1
								
								
							
								
								
							
								
									INSTALLA::ION And Operation Of Densitometers
								
								Author(s): James Bozeinan 
								
Abstract/Introduction:
								The direct measurement of a fluids flowing, density has many important advantages it can offer in flow measurement. The volumetric measurement of fluids in the liquid state requires that the flowing product be related to an equivalent unit volvime of H2O at a base temperature of say 60F. This is a commonly accepted practice due to the universal acceptance of water as a reference. In order to establish the relationship of the metered liquid at flowing condition to a unit volume of water at say another pressure and temperature, it is a must to know the density or specific gravity of the metered fluid. With many liquids this flowing density is not predictable and therefore must be measured by some means. The accurate volumetric metering of a fluid in the vaporous or gaseous state also requires some knowledge of the products density at flowing conditions as it passes through or around the primary flow element. In the case of orifice metering of a gas, it is very neces5ary to compensate somehow in the flow equation for the difference between (1) the density of the fluid which the discharge coefficient (or basic o:rlfice factor) is based upon, and (2) the actual density of the metered gas passing the orifice. This is commonly done via specific gravity (air 1,000), supercompressibility and pressure/temperature correction factors. Sometimes it becomes extremely difficult to accurately compensate for these critical factors when the flowing conditions are in a varying, changing state. Therefore, an on-stream density analyzer or transducer becomes a veiy logical tool to the measurement man seeking accurac
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									6811409C
								
								
							
								
								
							
								
									From Mcf To Mmbtu
								
								Author(s): Larry E. Powell 
								
Abstract/Introduction:
								With the decline in new U.S. reserve additions over the last decade, several interstate pipelines found it necessary to broaden their search for new gas reserve? to all parts of the world. Southern Natural Gas was one of these interstate pipelines. In July, 1978, we began serving a portion of our system with regasified LNG which comes from Algeria. This new foreign source of gas has an average BTU content of 1135 BTU/CF, while the traditional domestic sources of gas hae an average BTU content of 1027 BTU/CF. This large difference in BTU content raised many questions concerning the impact it would have on the operations of Southern and its customers. This paper will examine some of these questions, the answers to them, and basically describe how one major interstate pipeline company has made the change From Mcf to MMBTU.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									51877E79
								
								
							
								
								
							
								
									Recording Calorimeters Installation And Testing 
								
								Author(s): A. J. Kattawar 
								
Abstract/Introduction:
								The purpose of this paper is to recommend procedures istiich will be helpful in the installation and testing of a dependable and versatile recording calorimeter.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									2B7BBE88
								
								
							
								
								
							
								
									Installation And Operation Of Recording Calorimeters 
								
								Author(s): H.W. Nielson 
								
Abstract/Introduction:
								The Cutler-Hammer recording Calorimeter measures the total calorific value of combustible gas. It continuously samples, indicates, and records BTU per cubic f
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									2B86CDB5
								
								
							
								
								
							
								
									Thermal Energy Measurements 
								
								Author(s): William A. Fox 
								
Abstract/Introduction:
								Thermal energy, as generally used in the gas industry, refers to the amount of heat which may be produced through the combustion of .1 quantity of gas. Heat is energy in the process of being transferred and to most of us, is quantified in units of BTUs,
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									A3BD0C96
								
								
							
								
								
							
								
									Dbteiminaticw Of Caidrific Vftlue Of Natural Gas 
								
								Author(s): Richard L. Howard 
								
Abstract/Introduction:
								A new rrethod for determining calorific valie of natural gas has been developed. It is based on a proportional relationship between calorific value and the ratio of air to gas required to maximize the adiabatic flarre teirperature of mixtures of the two.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									70651F56
								
								
							
								
								
							
								
									Energy Measurehent Utilizing On Line Chromatograph
								
								Author(s): Arthur F. Haas 
								
Abstract/Introduction:
								The use of gas chromatographs for determination of the energy in natural gas is certainly not new. The laboratory chromatograph has been utilized for this purpose for many years quite successfully. The important difference in the system described in this paper is that the chromatograph is truly on line that is, it is located in the field at the sample tap and repeatedly samples directly from the line automatically. Previously, samples were taken in bombs and transported to the laboratory where a compositional analysis was run. It is now possible to take a sample from a flowing line, determine the composition and flow rate, compute the total energy and transmit the finished data to a remote location. This paper will concern itself with the system ENCAL II which is specifically designed as a total energy measurement syste
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									5E77164C
								
								
							
								
								
							
								
									Teghniiues Of Natural Gas Sampling 
								
								Author(s): Charles F. Drauce 
								
Abstract/Introduction:
								The scope of this paper is to introduce some different, but not necessarily new, ideas concerning the sampling of natural gas for the purpose of determining the heating value. Introduction Natural gas is sampled for an almost i n f i n i t e number of reasons in determining measurements for quality and quantity. The techniques for sampling :iiust vary according to the type of t e s t for whicT the sampling is done. Location of sampling p o i i t s, sample size, sample pressure, when the sample is taken and how the sample is taken, are a l l dependent on the desired end r e s u l t . The technician should understand the general purpose for wiiich a sample is being taken prior to actually taking the sample.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									37656110
								
								
							
								
								
							
								
									Measuring Station Inspection Program & Guide
								
								Author(s): N. B. Alpers 
								
Abstract/Introduction:
								Everyone involved in the measurement area of the gas industry is acquainted with the reference to his department as the cash register of the company. This term may well apply, for metering devices installed and operated by the gas measurement department are the basis for calculation of gas quantities in and out of the companys gas system. With ever-increasing prices at the wellhead, a detailed and workable inspection program is a must if we are to expect ac .rate and dependable service from our measuring stations.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									286B177C
								
								
							
								
								
							
								
									Measurement And Control Systems
								
								Author(s): Richard Cadmus 
								
Abstract/Introduction:
								Automatic control has long been commonplace in the oil and gas industry, with a high degree of sophistication in the refining and processing areas. The automatic controls used in the production and transportation of oil and gas have been relatively simple. Most efforts have been directed in the areas of measurement and communication. We have experienced dramatic changes in technology in oil and gas production in recent years, and as we approach the 1980s we are all very much aware of the changes in technology used in oil and gas production controls. Coal gasification and liquefaction, tertiary recovery techniques, biomass conversion, oil shale, and tar sands extraction are either realities or close to becoming realities.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									3309D307
								
								
							
								
								
							
								
									On-Line Computers For Custody Transfer
								
								Author(s): Joe Hawkins 
								
Abstract/Introduction:
								Accuracy in gas measurement has always been of utmost importance in i n d u s t r y however, as gas s u p p l i e s have decreased and the value of the product has gone up, the means for even more a c c u r a t e methods of measurement have been sought. The development of the gas shortage has brought about the i n t r o d u c t i o n of the c o n t r a ct with maxirauiD allowable d a i l y volumes and the providing of r a t h e r severe p e n a l t i e s for exceeding the a l l o w a b l e s . This c r e a t e s a need for d i s p a t c h e r s to know what the flow p i c t u r e is from minute to minute.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									E22EE7FF
								
								
							
								
								
							
								
									On-Site Flow Calculators And Transducers For Gas Turbine Meters 
								
								Author(s): Michael L. Matthews 
								
Abstract/Introduction:
								As the cost of potential of s the need for a ment of this v a greater impo precise measur are no longer sometimes leng the actual cus for the produc changing requi calculator/tra combination as position among avallable to o producing and the elling natural gas ccurate and timely aluable commodity rtance. The somet ement methods of t acceptable, nor ar thy time lapses be tody transfer and t . In light of th rements, the on-si nsducer/gas turbin sumes a more promi the measurement m ur industry. profit escala tes measuretakes on imes imhe past e the tween payment ese te e meter nent ethods
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									5D445CE7
								
								
							
								
								
							
								
									Basic Devices Amd Techniques For Supervisory Control Amd Telemetry Systems
								
								Author(s): Donald C. Mcbride 
								
Abstract/Introduction:
								Supervisory control and telemetry is the transmission and reception of information that deals with the measuring and/or controlling of a system process. The word telemetering is derived from Greek and Latin terms and means literally to measure at a distance. There are many ways of classifying telemetering. One method of classification is by the means of transmitting data, therefore electric (electronic), pneumatic, hydraulic, or mechanical.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									7E6E1562
								
								
							
								
								
							
								
									Appucatick Of Floff Computers For Gfis Measurement And Ccw 
								
								Author(s): Michael J. Keady 
								
Abstract/Introduction:
								T r a d i t i c n a l l y , o r i f i c e meter s i g n a l s have been recorded o n - s i t e by means of mechanical c i r c u l ar c h a r t r e c o r d e r s . These c h a r t s have been c:ollected weekly or monthly and i n t e g r a t e d for volune d e t e r mination. This procedure has a lengthy l e g between time of a c t u a l gas flew and tirre of r e p o r t i n g. With the advent of s p i r a l i n g gas p r i c e s ard p e n a l ty c l a u s e s for e x c e s s i v e r a t e d e l i v e r i e s , both customer and s u p p l i e r a r e looking towards quicker and more accurate methods of o b t a i n i n g flow ar.d t o t a l q u a n t i t y . By use of f i e l d iiDunted e l e c t r c n i c flow cortputers, flow information is processed en an i n s t a n t a n e o u s and continuous b a s i s.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									56879555
								
								
							
								
								
							
								
									Meter Station Noise Forecasting 
								
								Author(s): Paul Adams Fisher Controls Company Marshalltown, Iowa 
								
Abstract/Introduction:
								The scope of this presentation is limited to noise which originates in control valves. The generation, transmission, prevention, absoirption, isolation, and prediction of control valve noise will be studied.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									0670DA38
								
								
							
								
								
							
								
									Measurement Of Ethane Rich Streams
								
								Author(s): H. E, Meschke 
								
Abstract/Introduction:
								The measurement of an ethane rich stream can be thought of as a three step process. The first step in the process is to determine if the product should be measured in terms of volume or mass and which of these methods will produce the best results. In the case of an ethane rich stream, the physical properties are such that it would be difficult to apply conventional correction factors to obtain a net volumetric measurement. Therefore, by going to a mass measurement system we eliminate the need for these physical correction factors and still obtain an accurate measurement. The second step in the process is to determine the weight of the product. This can be done by measuring either the gravity or density of the stream under flowing conditions. The third step in the process is the sampling of the product to determine the streams composition. Once this is known, the volume of each component can be calculated, and the payment or exchange based on these calculated volumes.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									5044F5B0
								
								
							
								
								
							
								
									Calibrfttiotj Of Liquid Density Meters
								
								Author(s): Mr. Eldon Peninger 
								
Abstract/Introduction:
								Historically liquid density meters have teen a much ignored and misused piece of measuiement equipment. With the increased need for mass measurement, accurate densities are required. Calibration procedures have generally inferred density of the measured product. With the use of A.P.I, approved procedures, using a pyknometer, the density readings can be proved, thereby greatly improving overall measurement accuracy.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									2ED54CAC
								
								
							
								
								
							
								
									Turbine Meters For Liquid Measurement
								
								Author(s): Paul J. Lanasa 
								
Abstract/Introduction:
								Although the liquid turbine meter principle dates back many decades, the axial flow turbine meters presently employed for liquid measurement are quite new. The axial flow turbine meter was first used for driving the rotor and normally where accuracy of measurement was not of prime importance. Reliability was of greater importance, so parts were made rugged and the rotor was designed more to be non-clogging than to be accurate. However, through the evolution of technology, the turbine meter has maintained reliability and ruggedness while attaining a high degree of accuracy. Today, the meters used for water flow have accuracies of +0.25% over ranges of 10 to 1 or more while maintaining the same high degree of reliability and ruggedness as did their predecessors.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									BC0061C9
								
								
							
								
								
							
								
									Application Of The Micro-Computer To Hydrocarbon Liquid Measurement And Line Balance 
								
								Author(s): Joseph D. Perret 
								
Abstract/Introduction:
								The increased cost for hydrocarbons and governmental pressures for accountability have spawned a need for more accurate measurement of all hydrocarbon products. At the same time, the electronics and flow measurement industries have made significant strides in the ability to answer these challenges. One of the results is the micro-computer as applied to the flow measurement of liquid hydrocarbons. This paper looks at the capabilities of the presently available technology and on what we can expect in the future.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									318AB424
								
								
							
								
								
							
								
									Fundamentals Of Proving Domestic Meters
								
								Author(s): Budd Spitler 
								
Abstract/Introduction:
								The subject of proving domestic meters is complex and could very well take up three or four periods, but we will concentrate on the basic fundamentals such as 1) What is proving? 2) The basic proven and 5) Proving the meters.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									69F82D92
								
								
							
								
								
							
								
									In-Line Liquid Flow Provers
								
								Author(s): Joel David Bell 
								
Abstract/Introduction:
								Fluid measurement is usually performed under normal flowing conditions using a particular type of meter. Since a meters output can be influenced fay debris, mechanical wear, liquid slippage, etc., the meter must be verified on a regular basis against an accepted standard. The accepted standard for verifying said meter throughput is to check its output against a known volume. This known volume verification is called proving, and throughout the years many different devices have been used as provers: weigh tanks, volumetric prover tanks, master meters, etc.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									86242389
								
								
							
								
								
							
								
									Application Of Densitometers To Fluid Measurement 
								
								Author(s): Jack R. Hemphill 
								
Abstract/Introduction:
								With the advent of mass measurement, the density measuring instrument has become an extremely important part of the measurement package. Standard correction factors for temperature and compressibility can be used when the physical properties of a product are known, but due to solution mixing and intermolecular adhesion in ethane rich streams, these factors cannot be applied. Therefore, flowing density which can be considered as a factor of temperature and compressibility becomes a direct multiplier in the calculations to obtain mass. With this in mind it becomes obvious the accuracy of the densitometer is as equally important as volumetric accuracy. To achieve this needed accuracy the selection, proper installation, maintenance and provings must be accomplished.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									C0D081DF
								
								
							
								
								
							
								
									Liquid Meter Proving Techniques
								
								Author(s): Richard L. Redilla 
								
Abstract/Introduction:
								Since, in any measurement system, there is always some error present, it is desirable to have a method for determining the amount of error and correcting for it. There are three basic types of meter provers used for this purpose: 1. Gravimetric - The reference prover is a tank mounted on a weigh scale. The correct volume is determined by using the specific gravity or density of the fluid to connect the weight of the liquid to a volume. 2. Volumetric - The reference prover is an open-tank calibrated to deliver or contain a certain volume at 60F, 3. Displacement - This prover operates on the principle of displacing a known volume of liquid. Displacement of liquid is accomplished by forcing a displacer through a calibrated section of pipe.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									92D583E8
								
								
							
								
								
							
								
									Light Hydrocarbon Liquid Sampli
								
								Author(s): Carl G. Hefley 
								
Abstract/Introduction:
								In todays Increased world demand for energy, it has become mandatory to have extremely accurate measurement and sampling stations. On todays market, losses of significant quantities of product would be a disaster. The management of most companies, if not now, soon will be requiring the most accurate and reliable performance of all measurement and sampling systems. To meet these requirements, improvements have to be made on the way measurement and sampling systems operate.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									A342C195
								
								
							
								
								
							
								
									Gaugimg, Testimg Amd Runwing Of Lease T m Ks 
								
								Author(s): D. L. Arrick, G. C. Bell 
								
Abstract/Introduction:
								IHTRODUCTIOM A person would never write a personal check without first ascertaining the value of the item he is purchasing. When writing a run ticket a gauger is writing a weigh bill, bill of sale and a check combined in one document. It is written to allow a change of ownership or custody of the content of the tank. A gauger has the responsibility to see that accurate information is obtained and recorded. Each true datum can only be obtained by careful observation and correct use of proper tools.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									DF32A10C
								
								
							
								
								
							
								
									Maintenahce And Trouble Shooting Lact Units 
								
								Author(s): Arnold Tims 
								
Abstract/Introduction:
								Lease Automatic Custody Transfer (LACT) Unit used for s a l e of l i q u i d hydrocarbons from a product i o n tank b a t t e r y to a p i p e l i n e.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									EAE1EC55
								
								
							
								
								
							
								
									Automated Measurement On Loading Racks
								
								Author(s): John J. Connelly 
								
Abstract/Introduction:
								With the value of product stored and withdrawn in terminals ever increasing and therefore the requirements for security and accountability, so is the requirement for Terminal Automation. The need for real time Information by the operations department, the distribution department, the accounting department and, to some extent, regulations by the States and Federal Government make automation a must The use of mini and micro computers in modern terminal automation systems enables them to provide the security, control, data acquisition, formatting, and display required.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									6AC1F7AA
								
								
							
								
								
							
								
									Positivi: Displacement Liquid Meters 
								
								Author(s): James W. Kennedy 
								
Abstract/Introduction:
								Positive displacement(PD) liquid meters have long been the standard of measurement for the liquid petroleum industry. Over the years, numerous design Improvements have resulted in an expanded product line that now serves industrial as well as petroleum applications. While PD meters are ideally suited for many applications, they are not recommended for others. This paper will examine their strengths and weaknesses as well as design principles that are fundamental to capillary seal PD meters. It will also highlight the system and meter parameters that must be considered before an accurate meter selection can be made.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									55B47B8C
								
								
							
								
								
							
								
									Mass Measurement Of Natural Gas Liquids 
								
								Author(s): H. C. Tilley 
								
Abstract/Introduction:
								In any measurement system, the physical properties of the stream to be measured should be considered in the selection of the measurement equipment. Where the physical properties of the stream are known and conventional correction factors can be applied, volumetric measurement methods may be used. In natural gas liquid streams, however, conventional correction factors do not necessarily apply. The utilization of mass measuring methods may be applied to obtain accurate measurement where accurate physical correction factors cannot be determined.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									4E7B7036
								
								
							
								
								
							
								
									Correcting Instruments Applied To Displacement And Turbine Gas Meters
								
								Author(s): Thomas R. Comerford, Jr. 
								
Abstract/Introduction:
								Displacement and turbine gas meters provide an extremely accurate measure of the actual volume of gas consumed at the meter. If the density of the gas is also known at the meter, then the volume measured can be corrected to useful mass terms or to equivalent volume or standard volume for equitable contract billing. Correcting instruments calculate the density of the gas at the meter and directly modify the output frequency of the meter to provide a totalized reading in corrected contract volume. This effectively converts a volume meter into a mass meter. In order to understand how to best apply and use correcting instruments, we will discuss the details of how pressure and temperature measurements are used to provide correction of volume to mass. Dont let the details obscure the simplicity of what is being accomplished
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									A184D012
								
								
							
								
								
							
								
									High Accuracy LNG Tank Gauging 
								
								Author(s): R. A. Williams 
								
Abstract/Introduction:
								The buying, selling, and transportation of Liquefied Natural Gas (LNG) requires the use of sophisticated measurement systems for accurate determination of the total quantity and energy content for Custody Transfer reporting and safe cargo handling of this cryogenic product. These systems must meet strict safety standards for operation in a hazardous environment and, at the same time, provide accurate, reliable information for the storage, transfer, and data reporting required for both operational and financial accounting purposes.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									74D979C8
								
								
							
								
								
							
								
									Design Of Metering Systems For Tanker Offload
								
								Author(s): Don D. Haley 
								
Abstract/Introduction:
								The Tenagu Satu is on its way to your dock with 130,000 cubic meters of gas liquid at -40Celsius. The vessel has limited pumping for offloading, but the shipmaster has put out the word, He must be on his way to South America within 24 hours. Can your metering facility accomodate the implied requirements with the accuracy which todays product prices demand?
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									4A5FF72F
								
								
							
								
								
							
								
									Calibration Of Storage Tanks
								
								Author(s): F. R. Conway 
								
Abstract/Introduction:
								Tank Calibration is commonly referred to as Tank Strapping. Tank strapping was originally the work of placing metal straps around wooden containers this was generally before the Petroleum Industry came into being. The wooden containers most commonly used were for liquor or Whale Oil.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									BDF003F9
								
								
							
								
								
							
								
									Modern Automatic Tankgauging Systems
								
								Author(s): C. Eilers 
								
Abstract/Introduction:
								Efficient inventory control of liquids in lulk storage tanks requires accurate, reliable and safe systems for a continuous measurement of the product levels and t e m p e r a t u r e s.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									920CAE9B
								
								
							
								
								
							
								
									Controlling Surge In Liquid Pipeline
								
								Author(s): George m. Armstrong 
								
Abstract/Introduction:
								What is Surge? Surges or hydraulic transients, commonly known as water hammer are sudden increases or decreases of the total pressures in a piping system due to changes in velocity of the fluid in a pipeline. Change In velocity, such as would result frora the sudden closure of a valve in a flowing pipeline, causes the fluid to suddenly come to rest, resulting in a pressure increase in the system above the operating pressure. The energy associated with the moving fluid is converted into energy of pressure when it is suddenly stopped. In steady state pipeline flow, there is no change in the flow conditions at a point with passing time. The hydraulic grade line (HGL) elevation varies with two independent variables namely, the distance from the upstream end of the conduit & the flow rate. On the other hand, transient flow introduces time as a second independent variable such that both the flow velocity and the HGL elevation vary with both distance and the time elapsed from the start of a disturbance,
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									3A0137BA
								
								
							
								
								
							
								
									Clamp-Oh Ultrasonic Flowmeters Application Coasiderations And Field Test Results
								
								Author(s): T. R. Schmidt 
								
Abstract/Introduction:
								The primary attraction of the clamp-on ultrasonic flowmeters (Doppler and through transmission*) is their relatively low installed cost when added to existing operating systems. This factor has prompted a limited evaluation and test program to determine these meters suitability and characteristics when measuring typical liquids encountered in the petroleum industry. This paper will outline some of the observations and results of this effort.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									006B0DCA
								
								
							
								
								
							
								
									Measured Steps For Training The Measurement Man 
								
								Author(s): Jack I. Burger 
								
Abstract/Introduction:
								The increase of prices of all kinds of energy, especially natural gas which is approaching its true market value, creates the incentive for oil and gas companies such as Union Oil to revaluate their methods of handling and accounting for these fluids. We must expect scrutiny of existing gas product ion practices to intensify, and a high priority placed on accurate reporting of oil and gas streams,
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									EABAE94C
								
								
							
								
								
							
								
									International Standards Organizations Developments On Orifice Meter Standards 
								
								Author(s): E. L. Upp 
								
Abstract/Introduction:
								There is a new and different standard on orifice meters that has been approved and is published by the International Standards Organization (ISO) in their Technical Committee 30 (TC-30) on the Measurement of Fluid Flow in a Closed Conduit. The differences in this standard and the present AGA-3 Orifice Metering of Natural Gas will be examined so that those parties who deal in the International area will be aware of them and thus be better prepared in negotiations where the two standards are at issue.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									C1E6C916
								
								
							
								
								
							
								
									The Rules Of Epa And Industry In Protecting Our Environment
								
								Author(s): Wayne C. Smith, Dames & Moore 
								
Abstract/Introduction:
								An Overview of the R e s o u r c e C o n s e r v a t i on and R e c o v e r y Act (RCRA) R e g u l a t i o n s I n 1976 C o n g r e s s p a s s e d t h e R e s o u r ce C o n s e r v a t i o n and Recovery Act (RCRA). This Act i s d e s i g n e d t o c o n t r o l t h e d i s p o s a l o f s o l id w a s t e s and to p r o t e c t the g r o u n d w a t e r from p o l l u t a n t s c o n t a i n e d i n t h e s o l i d w a s t e s . This p a p e r d i s c u s s e s t h e r e q u i r e m e n t s of t h e RCRA r e g u l a t i o n s as r e l a t e d to t h e d i s p o s a l of s o l id h a z a r d o u s w a s t e s . E m p h a s i s w i l l be on I d e n t i f i c a t i o n of W a s t e s , S t a n d a r d s f or G e n e r a t o r s of H a z a r d o u s W a s t e , S t a n d a r d s f or T r a n s p o r t e r s of H a z a r d o u s W a s t e , P e r m i t s f or T r e a t m e n t , S t o r a g e or D i s p o s a l of Hazardous Waste a n d D e s i g n C r i t e r i a f o r a H a z a r d o u s W a s te D i s p o s a l F a c i l i t y.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									D6AC8E41
								
								
							
								
								
							
								
									Keeping Osha In Perspective
								
								Author(s): Goiiier J. Lewis 
								
Abstract/Introduction:
								The Williams-Steiger Occupational Safety and Health Act of 1970, commonly referred to as OSHA has been with us for almost ten years. This act, legislated by Congress, established Federal Safety and Health Standards that were adopted from National consensus standards at the time of the Acts introduction to the American Industrial Scene.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									8C32C3A0
								
								
							
								
								
							
								
									Large Capacity Displacement Meters 
								
								Author(s): Donald H. Knapp 
								
Abstract/Introduction:
								Although Che design of bellows type Positive Displacement meters dates back well into the last century, it has now and will continue to have wide acceptance in our industry. Other types of measurement may appear at first glance to be more advanced, but this type is the only one that has virtually 1007o rangeabll ity, that is, the ability to measure gas from full rated capacity of the meter down to the smallest pilot load.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									3DB4681F
								
								
							
								
								
							
								
									Fundamental Gas Laws 
								
								Author(s): F. Mark Townsend 
								
Abstract/Introduction:
								Gas measurement Is the determination of the volume of a gas at a particular tGmperatL.re and pressure. The measurement should be as accurate as possible, making use of the best data and techniques available. The gas quantity is usually expressed in cubic feet or cubic meters at some specific temperature and pressure.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									C56E5A56
								
								
							
								
								
							
								
									The Calculation Of Gas Properties-Past, Present And Future
								
								Author(s): Kenneth E. Starling 
								
Abstract/Introduction:
								Gas properties calculation methods used in the past and at the present time are discussed and a projection of future gas properties calculation methods is presented. Note Is made of the fact that gas properties calculation methods prior to about 1960 generally were made using tables and/or charts, while since the early 1960s the computer has been utilized extensively. Some of the inadequacies of present-day gas properties calculation methods are noted and improvements which can be expected in the near future are discussed. The compressibility factor of natural gases is given particular attention.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									1D83346B
								
								
							
								
								
							
								
									Overall Measurement Accuracy
								
								Author(s): Howard W, Berghegger 
								
Abstract/Introduction:
								When the word measurement is mentioned, the majority of the gas industry measurement personnel automatically convert their thoughts to a meter. The meter contributes only 1/2 to 1/4 toward the total science of measurement depending on the application,
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									768563F5
								
								
							
								
								
							
								
									Flow Measurement By Vortex Shedding Meters
								
								Author(s): G, L. Williamson 
								
Abstract/Introduction:
								THE VORTEX SHEDDING ELEMENT Accurate, low-cost flow measurement is important to almost everyone associated with the process industry. Flow measurement affects many decisions made in ordinary plant operation from the engineer who depends on accuracy for material and energy balances to improve the productivity of his operation, to the manager who is not only concerned about the capital cost associated with flow measurement, but also the continued maintenance costs. A significant step has been taken in bridging the gap between economy and accuracy with the introduction of the vortex flowmeter.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									BE437324
								
								
							
								
								
							
								
									Multiport Averaging Pitot Tube In Gas Measuring & Control 
								
								Author(s): J. R. Mortensen 
								
Abstract/Introduction:
								- Plow measuring is a necessary parameter in all societies. Frequently , we look into the past to discover something new. Taking long proven methods and making them easier to use, often reinvents a new field of measurement. Such is the case with the Meriam Accutube, a multiport averaging pitot tube.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									EB42ABD8
								
								
							
								
								
							
								
									M)HITOE:NG Daily Demajto Of Gas Volumes
								
								Author(s): James B. Eubanks 
								
Abstract/Introduction:
								The monitoring of daily demand of gas volumes has been a routine way of life in the gas industry, He monitors them I monitor him you monitor mej and, of course, the government monitors us all. It keeps everyone honest and it is perhaps the single most important factor that has broujjht about the accuracy in measurement experienced today. That is the need to stay a little ahead of the guy monitoring.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									52ACA91F
								
								
							
								
								
							
								
									What The Office Group Expects From The Field Group 
								
								Author(s): David A. Ward 
								
Abstract/Introduction:
								The functions of our Measurement Department have become increasingly more complex in the last few years. Federal and State regulations, and the demand for better measurement accuracy from both purchasers and producers, have placed new burdens on our industry. These requirements, coupled with pressures from the financial groups for earlier closings, demand that efficiency be maintained at the highest possible level
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									B35DAF6B
								
								
							
								
								
							
								
									What The Field Group Expects From The Office Group 
								
								Author(s): Robert L. Davis 
								
Abstract/Introduction:
								The accuracy and reliability of information used by the Gas Measurement Department to compute volumes of gas either purchased or sold depends on two groups working closely as a team. These two groups are the Office Group and the Field Group.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									09BF6ADB
								
								
							
								
								
							
								
									Conditioning Natural Gas For Measurement And Transportation
								
								Author(s): B I L L G. Spradlin 
								
Abstract/Introduction:
								This presentation is based on a number of years of experience in the field of producing and conditioning natural gas. A recent experience in the development and start up of the Union Island Gas Field in Northern California will be used to illustrate some of the requirements for conditioning gas for measurement and transportation.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									CD890E33
								
								
							
								
								
							
								
									System Of Transfer Proving
								
								Author(s): Wilbur W. Lints 
								
Abstract/Introduction:
								Prior to the mid 1960s the only available method for field testing large capacity positive displacement meters was the Low Pressure Flow Prover or the Critical Flow Prover. Although tl ow provers are commonly referred to as ficld provers, in many instances they are used at the meter repair shop in lieu of a bell prove r of adequate size. For example, a diaphragm type meter having a capacity of 10,000 cu. ft . per hour would require at least a 20 cu. ft. bell prover to obtain the necessary hourly floi- rate for proving and adjusting.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									E86112DD
								
								
							
								
								
							
								
									About Ishm 1980 
								
								 
								Abstract/Introduction:
								Collection of documents about ISHM including table of contents, event organizers, award winners, committee members, exhibitor and sponsor information, etc.
								
									Go to Download Page
									
									Email Reference
								
								Document ID:
									395D753D