Next Generation Prover Technology For High Flow Rates & Large Bore Meter Market
Abstract/Introduction:
Definition of Provers Devices with known traceable volume designed to calibrate (prove) liquid flow meters accuracy and repeatability under actual operating conditions in the field or calibration laboratories . API SVP Definition the term SVP applies to any prover that collects 10,000 pulses between detectors APIs Updated Definition - Unidirectional Captive Displacement Provers refers to type of displacer and switches Unidirectional Captive Displacement Prover In 2010 FMD was granted the first of six patents for Prover design innovations
Go to Download Page
Email Reference
Document ID:
BC4FDF00
Methodology For Liquid Ultrasonic Flow Measurement Within The Laminar To Turbulent Transitional Zone
Author(s): Dave Seiler
Abstract/Introduction:
Industry acceptance of Liquid Ultrasonic is driving technology growth Technology is well entrenched into custody transfer type applications Manufacturers are continuing to invest and drive for ease of use and improvements in measurement Customers are applying the technology into more complex applications
Go to Download Page
Email Reference
Document ID:
345A68F1
Ultrasonic Meter Technology From Wellhead To Gate Station
Abstract/Introduction:
Bi directional storage facility Pressure range 200 - 1500 PSIG Flow 2 to 60 FPS Sand Oil water carryover 1/8 to sand oil build up common
Go to Download Page
Email Reference
Document ID:
9D7C6A32
Extending Ultrasonic Gas Flow Metering Beyond Transmission Applications
Author(s): Jim Bowen
Abstract/Introduction:
Gas USMs have found a home in high volume Transmission applications because of Economies of scale Smart maintenance via diagnostics Available calibration facilities Accuracy and Repeatability (or Uncertainty) But what of upstream and downstream possibilities?
Go to Download Page
Email Reference
Document ID:
2DCEEC4E
Criterios Generales Para La Seleccion De Sistemas De Medicion De Flujo De Gas En Transferencia De Custodia
Author(s): Johan Arenas Bustamante
Abstract/Introduction:
Punto de Transferencia de Custodia: Es el sitio donde se transfiere la custodia del gas entre un Productor - Comercializador y un Transportador o entre un Transportador y un Distribuidor, un Usuario No Regulado, un Almacenador Independiente, un Usuario Regulado atendido por un Comercializador (no localizado en reas de servicio exclusivo), una Interconexion Internacional, entre dos Transportadores, y a partir del cual el Agente que recibe el gas asume la custodia del mismo . (Fuente . R . CREG - 041 - 2008 Art 1 R . CREG - 071 - 1999 Cap . I . Num . 1 . 1
Go to Download Page
Email Reference
Document ID:
B6B067CC
Microprocessor Based Measurement Devices
Abstract/Introduction:
Low Cost of lifetime ownership Quality Reliability Security and Integrity without compromise Configurability - Not Programming Connectivity Innovation through Proven Technology Regulatory Compliance
Go to Download Page
Email Reference
Document ID:
5EB233F9
Ultrasonic Gas Flowmeter Calibration Intervals
Author(s): Thomas Kegel
Abstract/Introduction:
AGA 9: 1998, 2007 no guidance on recalibration interval Canada: regulated measurement five year recalibration interval United States unregulated measurement not present in most contracts
Go to Download Page
Email Reference
Document ID:
D2179C95
Sing Technology To Reduce Maintenance Costs & Measurement Uncertainty For Gas Usm Facilities
Author(s): Ed Hanks
Abstract/Introduction:
Using Technology to Reduce Maintenance Costs & Measurement Uncertainty for Gas USM Facilities
Go to Download Page
Email Reference
Document ID:
32F43A8F
South American Custody Transfer Conference
Author(s): John Lansing
Abstract/Introduction:
AGA TMC started an Ultrasonic Technical Note in 1994 Chaired by Gene Tiemstra, Bob Pogue & Phil Barg all of Nova Pipeline (Calgary) Took approx. 2 years to complete Published March 1996 - ????? 1996 AGA TMC then began work on 1 st Edition of AGA 9 Chaired by John Stuart of PG&E Three manufacturers: Daniel, Instromet & Panametrics 8 Draft revisions and 2 years later the 1 st Edition was released Published in June 1998
Go to Download Page
Email Reference
Document ID:
D959E1CE
Reduciendo Los Costos Y El Riesgo Economico En Transferencia De Custodia De Hidrocarburos Mediante El Diseo De Procesos De Medicion Basados En Estimacion De Incertidumbre
Abstract/Introduction:
Generalidades de la Transferencia de Custodia Implementando Procesos de Medicion Solucion Tradicional Solucion Integral Diseo metrologico Incertidumbre y riesgo economico Conclusiones
Go to Download Page
Email Reference
Document ID:
D78F7FE2
Natural Gas Testing Demonstrates Calibration Fluid Flexibility And Secondary Verification Of A Coriolis Meter
Author(s): Marc Buttler
Abstract/Introduction:
As a particle inside a rotating body moves toward or away from the center of rotation, the particle generates inertial forces that act on the body
Go to Download Page
Email Reference
Document ID:
9049C4A8
El Bdc De Promigas. Un Laboratorio Acreditado Para Calibrar Medidores De Transferencia De Custodia Con Gas Natural A Alta Presion
Author(s): Jennyfer Tatiana Chaves Rojas
Abstract/Introduction:
HISTORIA Diseo y puesta en servicio Alcance de medicion Video Banco de Calibracion ASPECTOS TCNICOS Infraestructura Filosofia de operacion Capacidad de Medicion y Calibracion Aseguramiento de los resultado . RESUMEN Y CONCLUSIONES
Go to Download Page
Email Reference
Document ID:
EC50F0E2
Force Technology Builds The Worlds Largest Calibration Loop For Calibration Of Natural Gas Metres
Author(s): Jesper Busk Thomas Boy Jacobsen
Abstract/Introduction:
High Pressure calibration facilities at FORCE Technology Traceability and uncertainty Intercomparison in EuReGA
Go to Download Page
Email Reference
Document ID:
634B0652
1 Noviembre 2014 Seleccion De Medidores Para Tc Seleccion De Medidores Para La Transferencia De Custodia De Liquidos
Author(s): Tony Petitto
Abstract/Introduction:
2 2 Noviembre 2014 Seleccion de medidores para TC Medidores para la Transferencia de Custodia de Liquidos Medicion Directa Medidores de Desplazamiento Positivo (PD) API MPMS 5.2 Medicion Indirecta Medidores tipo Turbina API MPMS 5.3 Medidores Ultrasonicos API MPMS 5.8 Medidores Masicos ( Coriolis ) API MPMS 5.6 Equipos que miden la velocidad del fluido
Go to Download Page
Email Reference
Document ID:
D4F1F17E
Coriolis Mass Flow Meter For Gas Measurements
Abstract/Introduction:
Coriolis Mass Flow Meter for Gas Measurements Technology and Applications Coriolis Principle, Operation and Types of Flowmeters Special Considerations for Gas Flow Measurement Calibration and gas verification Common applications
Go to Download Page
Email Reference
Document ID:
C197E34A
Uso De Probadores Master Meter Para Calibracion De Medidores De Flujo De Liquidos En Campo
Abstract/Introduction:
Generalidades sobre el metodo master meter Tecnologias de medicion utilizadas como master meter Campos de aplicacion Requerimientos operativos y metrologicos Calibracion en masa: fuentes de incertidumbre Calibracion en volumen: fuentes de incertidumbre Fuentes de incertidumbre criticas Ventajas y desventajas de los probadores master meter
Go to Download Page
Email Reference
Document ID:
FD6904E2
Analytical Sampling Techniques For Analysis Of LNG
Author(s): Ken Thompson
Abstract/Introduction:
Refrigerated light hydrocarbon fluids First ed. published in 1991 Second ed. published in Mar. 2007 Methods for continuous and intermittent sampling of LNG Sample probe Sample Vaporizer Sample Holders Sample Cylinders
Go to Download Page
Email Reference
Document ID:
7ACCAD58
Fluid Flow Conditioning
Abstract/Introduction:
There is no flow meter on the market that needs flow conditioning. All flow meters are effective without any type of flow conditioning
Go to Download Page
Email Reference
Document ID:
B76A1DD0
Coriolis Gas Measurement
Author(s): Marc Buttler
Abstract/Introduction:
Tightening of performance requirements from 1.0% to 0.7% ? Water calibration transfers to gas only when the manufacturer has proof of testing by a 3 rd party. Additional meter verification steps will guide the user on the need to flow test Flow testing can be performed in the field per new guidelines New appendices added: Coriolis Gas Flow Measurement System Coriolis sizing equation Coriolis Uncertainty section and Example Uncertainty Calculation
Go to Download Page
Email Reference
Document ID:
07D0AF14
Installation Effects On Ultrasonic Flow Meters For Liquids
Author(s): Jan G. Drenthen, Pico Brand Peter Van Brakel
Abstract/Introduction:
ccuracy depends on Acoustic path configuration The number of paths The calculation schedule of individual paths Major issues are: Erratic flow profile changes in the Transition region Temperature stability Profile distortions
Go to Download Page
Email Reference
Document ID:
28D181C5
Experiencias De Medicion En Transferencia De Custodia Para Liquidos De Gas Natural
Author(s): Jimmy Sotero Felipe Miranda
Abstract/Introduction:
LQUIDOS DE GAS NATURAL (LGN) Hidrocarburo liquido liviano Alto grado de volatilizacion Compuesto principalmente por Propano nico en Per
Go to Download Page
Email Reference
Document ID:
226DAA63
The Effect Of Water In Oil On The Performance Of Coriolis Meters
Author(s): Terry Cousins Richard Steven Tom Kegel
Abstract/Introduction:
This paper discusses the potential use of Coriolis meters for the flow measurement of oil/water mixtures. The Coriolis meter is potentially well suited to this adaption to oil with water metering. The physical principles on which it operates allow the meter to output multiple variables : mass flow rate. volume flow rate. fluid density . Diagnostics
Go to Download Page
Email Reference
Document ID:
C96049F4
Liquid Meter Provers
Author(s): Dave Seiler
Abstract/Introduction:
When ownership of petroleum is transferred from one company to another, a financial transaction occurs. Accurate measurement of the transferred petroleum is critical to ensure an equitable exchange of money for petroleum. Flow measurement equipment serves as the cash register for this exchange
Go to Download Page
Email Reference
Document ID:
CE84A848
The Importance Of Dynamic Testing
Author(s): Jim Smith
Abstract/Introduction:
Dynamic testing theory Liquid ultrasonic meter fundamentals Reynolds number and velocity profile Dynamic testing process Multi - path test results Summary and conclusions
Go to Download Page
Email Reference
Document ID:
D87642AF