Title: Volume Correction Of Domestic Gas Metering In Korea
Author: Kyung-Am Park
Source: 2012 International Symposium on Fluid Flow Measurement
Year Published: 2012
Abstract: The reference conditions of natural gas transaction are 0 ? and 1.01325 bar in Korea. Gas temperature and pressure of actual gas flow are quite different from the reference conditions. In summer time, atmospheric temperature is higher than are 0 ? and atmospheric pressure is lower than1.01325 bar. But the situation is reverse in the winter. Volume correctors are used to calculate gas volume at the reference conditions in the industrial and commercial gas flow meters. Volume corrector is expensive to use in the home. Volume correction effect in the home is usually less than cost of volume corrector even though gas is used for cooking and heating. So it is one of the best methods to use volume correction factor.