Email Document Reference

Enter your email address below and the reference for this document will be sent to shortly from webmaster@ceesi.com.

Title: An Ultrasonic Meter For Stratified Wet Gas Service
Author: Klaus J. Zanker
Source: 2001 North Sea Flow Measurement Workshop
Year Published: 2001
Abstract: Recent tests of ultrasonic meters in wet gas service have shown that the most consistent connection between internal parameters of a 4-path SeniorSonic meter and LVF (Liquid Volume Fraction) is seen in mist flow. However, it has proved difficult to achieve this flow regime in practice. Mist flow is seen at high gas velocities and high pressure, and is found only at the edge of the operating envelope of all available wet gas test facilities. The most common flow regime encountered during testing has been stratified.