Title: Ultrasonic Meter Installation Configuration Testing
Author: Terrence A. Grimley
Source: American Gas Association 2000
Year Published: 2000
Abstract: This paper presents the results of recent multipath ultrasonic flow meter testing using proposed standard installation configurations. A suite of flow tests was applied to three types of commercially available 12-inch multipath meters to establish their performance in response to the proposed test suite. The tests are intended for verification of a meters performance relative to the levels required for compliance with AGA Report No. 9. The tests included piping configurations with single and double elbow combinations (in plane, and out of plane) and meter tube configurations with and without flow conditioners. The work was sponsored by the GRI and was performed at the GRI Metering Research Facility at Southwest Research Institute.




In order to prevent spam and automated file downloads for documents within the Measurement Library, please follow the instructions below and then you will be able to email a reference to this article.