Email Document Reference

Enter your email address below and the reference for this document will be sent to shortly from webmaster@ceesi.com.

Title: Nims Research Progress On Flue Gas Flow Rate Measurement
Author: L. Zhang C. Wang H. Li X. Liu
Source: Flomeko 2016
Year Published: 2016
Abstract: The p oint source greenhouse gas emissions direct measurement approach is an effective complement to Chinese carbon trading market accounting methods. The main source of uncertainty in greenhouse gas emissions direct measurement is flue gas flow rate measurement . China does not have flue gas flow rate standard facility , moreover f lue gas flow rate measur ement method s need to be improved. In order to study flue gas flow rate accura te measurement methods and calibration methods, NIM buil t a Smoke S tack S imulator (SMSS) . Th is facility can generate different swirls to simulate stack gas flow field s , which can be used to study flue gas flow rate measurement method s . This facility can also be used for standard pitot tube s calibration . Early in the design, Computational Fluid Dynamics ( CFD ) numerical simulation was used to evaluat e the effect of environmental conditions on the performance of the SMSS. T h e structure s and function s of main parts of SMSS were d escribed in detail.




In order to prevent spam and automated file downloads for documents within the Measurement Library, please follow the instructions below and then you will be able to email a reference to this article.





Copyright © 2025