Email Document Reference

Enter your email address below and the reference for this document will be sent to shortly from webmaster@ceesi.com.

Title: Proficiency Test For Measurement Equivalence In Water Flow Metering With Coriolis Mass Flow Meters In South Korea
Author: Sejong Chun Byung-Ro Yoon Soo-Jin Kim
Source: Flomeko 2016
Year Published: 2016
Abstract: There are more than twenty accredited laboratories for flow measurement in South Korea according to KOLAS, the Korea Laboratory Accreditation Scheme. Among them, twelve accredited laboratories participated in the proficiency test for water f low metering arranged by KASTO, the Korea Association of Standards and Testing Organization, in 2015. KRISS prepared for the proficiency test with the water flow standard system (WFSS), of which measurement range was between 3.6 m 3 /h - 200 m 3 /h. The participating laboratories were divided into three groups to test low flow range (3.6 m 3 /h - 12 m 3 /h) and high flow ranges (40 m 3 /h - 80 m 3 /h and 40 m 3 /h - 200 m 3 /h). The transfer standards were two Coriolis mass flow meters. All the participating laborato ries satisfied the measurement equivalence with the WFSS at KRISS. However, there was one example which demonstrated the importance of density measurement for volume flow metering with the mass flow meters.




In order to prevent spam and automated file downloads for documents within the Measurement Library, please follow the instructions below and then you will be able to email a reference to this article.





Copyright © 2025