Title: Design, Operation And Problems Associated With Prover Detector Switches
Author: Wilham R. Young Jr.
Source: 1998 International School of Hydrocarbon Measurement
Year Published: 1998
Abstract: A meter prover is used to calibrate meters to estabhsh a meter factor. The volume that passes through the meter is compared to the knovm prover volume. This volume is the displacement of the liquid between the detector switches on the prover. The displacement is measured either by a sphere or a piston from the activation of the first detector switch to the activation of the second detector switch. This volume between tht detector switches is determined by a calibration procedure known as the WaterDraw method. The detector switches are a very important part of establishing a meter factor.