Title: Determination Of Water Vapor Content And Hydrocarbon Dew Point In Natural Gas
Author: G. D. Turner
Source: 1975 International School of Hydrocarbon Measurement
Year Published: 1975
Abstract: The determination of a dew point is probably one of the most controversial subjects in the gas industry today. It has not been too many years past that the water content of natural gas was lot, for the most part, considered too great a factor in gas transmission,. During the past forty years this idea has changed since large supplies of natural gas are being transported to the northern part of the United States. Therefore it was necessary for research and Experimentation to make available a greater knowledge of the control of water vapor in latural gas. Natural gas as it comes from the wellhead is known to be saturated with water /apor. If this vapor is not controlled before :he gas enters the transmission lines, serious :rouble can result.