Title: Installation Effects In Ultrasonic Gas Flowmeters
Author: Hilko Den Hollander
Source: 2015 European Flow Measurement Workshop: Ultrasonic & Coriolis Metering
Year Published: 2015
Abstract: Flow conditioner of meter B produced ultrasonic noise at flowrates 2200 m3/h. Flow conditioner modified to reduce noise production. After modification less noise and only starting at 2450 m3/h. Modifications caused flow profile of meter B to be slightly asymmetric. Noise production by flow conditioner occasionally happens and is a typical case of bad luck