Title: Arkla Energy Resources
Author: Vic Crowe
Source: 1988 International School of Hydrocarbon Measurement
Year Published: 1988
Abstract: e meter tube is often referred to as the imary Device, since it, along with the orifice ate, is essential to proper measurement. The ndition of the tube must be correct in eting the requirements or the specifications A.G.A. Report No. 3 and if these conditions e not complied with and maintained, no matter at type of secondary device or meter that is stalled, the measurement can never be correct. e primary purpose of the meter tube is to liver the fluid flow to and through the ifice plate under a controlled condition. e tube consists of two sections of pipe cated on the upstream and the downstream the orifice holding device. This pipe must et certain specifications and criteria. ese specifications are set forth in the G.A. Report No. 3 and should be followed in e manufacture of the meter tube. All of ese specifications are for the purpose of iminating turbulence.