Title: Evaluation Of 12-INCH Polyethylene Pipe For Cinergy Gas Distribution
Author: Christopher W. Ampfer
Source: American Gas Association 2004
Year Published: 2004
Abstract: This report was prepared to provide Cinergy Gas Engineering with a rational for making a decision between 12 MDPE, 12 HDPE, and 12 steel pipe (X-42, 0.219 wall thickness) for use in replacing the remaining 12 main in the AMRP. Differences in the physical properties, engineering properties, material costs, installation costs, and maintenance costs of the pipe materials are compared. Information for this report was gathered from Cinergy Gas Engineering records, published papers, pipe vendors, and other natural gas companies. The unit costs estimated in this report, and the data used to estimate the unit costs are considered confidential to Cinergy Gas Engineering Department therefore, differences in costs are presented rather than presenting the actual cost data.