Title: Clamp - On Ultrasonic Flow Meter Application And Performance
Author: William E. Frasier
Source: 2014 American School of Gas Measurement Technology
Year Published: 2014
Abstract: Clamp - on meters are specified to achieve one to three per cent uncertainty. Manufacturers cannot control the quality of a given field installation and must provide latitude. Lab testing has demonstrated m any installations perform at an accuracy level range of 1%. If a reliable installation technique is maintained, the clamp - on meter will often perform better than manufacturer standards. Further , the meter control units have piecewise linear error correction schemes such that they can be adjusted to reference flow rates as afforded at a flow lab