Title: Hands-on Water Cut By Coriolis Meter
Author: Don Hammil
Source: 2017 Canadian School of Hydrocarbon Measurement
Year Published: 2017
Abstract: A flow computer can determine the instantaneous water oil ratio from the live measured density if the density of the water is constant and the density of the oil is constant. Example S.G. of water is known to be 1.05 S.G. of oil is known to be 0.85 Instantaneous measured density 0.95 Therefore the current ratio of oil to water is 50%.