Title: Flow Conditioning
Author: Cpa
Source: 2016 CEESI North American Custody Transfer Measurement Conference
Year Published: 2016
Abstract: 6/27/2016 1 Fluid Flow Conditioning CEESI 2016 CPA Flow Conditioning 2016 June 27, 2016 Flow Conditioning There is no flow meter on the market that needs flow conditioning. All flow meters are effective without any type of flow conditio ning. CPA Flow Conditioning 2016 June 27, 2016 Flow Conditioning Why do we want to use flow conditioners then? Can eliminate up to 80 -90% of pipeline swirl. Restore flow profile symmetry and eliminate distortions. Isolates the flow meter from upstream disturbances. Allows much shorter meter runs to be used with much higher repe atability. Improves the benefits of many USM diagnostics by providing flow stability. Helps with noise or pulsation problems. Helps balance the pressure, velocity and flow rate of meter tub es running in parallel. They UNLOAD the flow meter, helping it become even more accurat e.