Email Document Reference

Enter your email address below and the reference for this document will be sent to shortly from webmaster@ceesi.com.

Title: Ultrasonic Flowmeter For Accurately Measuring Flare Gas Over A Wide Velocity Range
Author: Lei Sui*, Toan H. Nguyen, James E. Matson, Peter Espina And Ivantew
Source: Flomeko 2010
Year Published: 2010
Abstract: Flare gas ultrasonic flow measurement has now been well established with more than 3000 units installed worldwide in process plants and refineries. One of the remaining technical challenges in flare gas ultrasonic flowmetering is to deal with extremely high flare flows (greater than 80 m/s) during emergency flaring. High flare flows introduce soaring flow noise, cause ultrasonic beam drift and thus deteriorate ultrasonic signal quality, leading to an ultimate failure of the flare gas flow measurement. In this paper, the ultrasonic propagation in flare gas has been studied, the beam drift due to gas flow has been investigated and improvements from both mechanical and transducer perspectives have been made. An improved flare gas ultrasonic flow meter has been developed to demonstrate the accurate measurement of air flow up to 123.7 m/s.




In order to prevent spam and automated file downloads for documents within the Measurement Library, please follow the instructions below and then you will be able to email a reference to this article.





Copyright © 2025