Title: Diagnosis And Mitigation Of Contamination Build-Up In Multipath Liquid Ultrasonic Meters On The Danish Oil Pipe
Author: Gregor J Brown Lars Bach
Source: 2016 North Sea Flow Measurement Workshop
Year Published: 2016
Abstract: This paper describes an investigation and remedial work carried out on multipath liquid ultrasonic meters installed on the Danish Oi l Pipe, owned by DONG Oil Pipe A/S (DOP). The meters in question were installed i n an effort to improve the performance of the onshore metering system at the r eceiving end of the pipeline. When the second of two replacement meters was insta lled, 10 months after the first, and the two meters operated in series, it wa s discovered that the first replacement meter was not in good agreement with th e second meter. Investigations revealed that the problem was the re sult of contamination build-up inside the first meter and work began to understand and to attempt to resolve the problem