Email Document Reference

Enter your email address below and the reference for this document will be sent to shortly from webmaster@ceesi.com.

Title: Ultrasonic And DP Meter Responses To Wet Natural Gas Flow
Author: Richard Steven Charlie Britton Josh Kinney
Source: 2015 European Flow Measurement Workshop: Ultrasonic & Coriolis Metering
Year Published: 2015
Abstract: Ultrasonic and DP Meter Responses to Wet Natural Gas Flow Richard Steven - CEESI Ultrasonic and DP Meter Responses to Wet Natural Gas Flow Richard Steven, Charlie Britton & Josh Kinney DP meters are extensively used with wet gas flows. Ultrasonic meters are being promoted as a viable alternative to DP meters in wet gas applications. Lets discuss the known wet gas performance of Venturi, orifice and ultrasonic meters in terms of: The gas flow rate prediction bias & published correction factors, & The meters relative abilities to register wet gas & monitor the liquid loading.




In order to prevent spam and automated file downloads for documents within the Measurement Library, please follow the instructions below and then you will be able to email a reference to this article.





Copyright © 2025