Title: Installation Effect On Ultrasonic Flowmeters And Evaluation Of Computational Fluid Dynamics Prediction Methods
Author: Gregor Brown, Craig Coull, Neil Barton
Source: 2005 South East Asia Flow Measurement Conference
Year Published: 2005
Abstract: This paper presents the results of a detailed investigation of installation effects on the performance of transit time ultrasonic flow meters. Extensive laboratory tests and Computational Fluid Dynamics (CFD) modelling have been performed. Laboratory tests have been carried out on a triple bend installation. Three meters have been tested two clamp-on meters (using reflected diametric paths) and a dual-cross mid-radius meter. Each meters performance has been analysed and explanations offered as to why the observed effects occur. Path velocity data has also been recorded from the dual-cross midradius meter.