Title: Critical Flow Prover Method Of Field Testing Large Capacity Meters
Author: J. E. Jim Gross
Source: 1984 International School of Hydrocarbon Measurement
Year Published: 1984
Abstract: The critical flow prover method of field testing large capacity meters is applicable when the absolute downstream pressure Is approximately one-half of the absolute upstream pressure. Critical flow condition exists when the velocity of the gas through the orifice reaches an absolute maximum. Absolute maximum velocity exists when the absolute downstream pressure is 0.528 of the absolute upstream pressure.




In order to prevent spam and automated file downloads for documents within the Measurement Library, please follow the instructions below and then you will be able to email a reference to this article.