Title: 3 Coriolis Meter Perturbation Testing
Author: Gary Mccargar
Source: 2014 North American Custody Transfer Measurement Conference
Year Published: 2014
Abstract: Applicable Industry Standards and Guidelines Primary Standards and Guidelines American Gas Association - AGA AGA 11 Report American Petroleum Institute - API API 14.9 (adoption of the AGA 11 Report) as a standard AGA 11 selected sections Section 6 - Performance Criteria (minimum) Section 7 - Gas Flow Calibration requirements does not specify the flow range to test the meter does specify a minimum of 5 flow points for testing Section 8 - Installation Requirements does not specify any upstream or downstream piping requirements does not specify any flow conditioning suggest consulting with manufacturer for installation requirements does provide a suggested configuration void of any dimensions or lengths