Title: An Experimental Derivation Of An Expansibility Factor For The V-Cone And Wafer-Cone Meters
Author: R. J. W. Peters, m. R. H. Reader-Harris, D. G. Stewart
Source: 2001 North Sea Flow Measurement Workshop
Year Published: 2001
Abstract: The V-Cone meter is a differential pressure device that has been developed and tested since 1985 and is now well understood and accepted as a viable flow measurement device. It is widely used in many industrial applications to measure a variety of fluids over a wide range of temperatures and pressures. The choice of the V-Cone can be based on the relatively short upstream lengths required and the ease of operation over a wide turndown ratio relative to an orifice plate.