Email Document Reference

Enter your email address below and the reference for this document will be sent to shortly from webmaster@ceesi.com.

Title: Measurement Of Forward And Reverse Natural Gas Flows In Closed Conduits By Differential Pressure Cone Flow Meters And Ultrasonic Meters
Author: Larry Whitaker Philip A. Lawrence
Source: 2009 South East Asia Flow Measurement Conference
Year Published: 2009
Abstract: The use of differential pressure type meters to measure accurately a bi-directional gas flow in a pipeline can have major measurement uncertainty issues due to the geometric difference in the differential producer element shape when used in the reverse direction. Meter discharge coefficients may be different in these particular cases for geometric devices such as concentric,square edged and flange tapped orifice flow meters and Venturi meters. Current national and international measurement standards state that bi-directional flow measurement is not permitted using orifice plate type flow meters for a good measurement uncertainty and that meter runs dedicated for each direction must be used in this application. This paper details the recent experience and testing of differential pressure cone meters used to measure high pressure natural gas to custody transfer standards and as check meters for the CTM Gas Ultrasonic Meters (USMs) at a natural gas storage and transmission facility in New Mexico USA The cone meters mentioned in this paper were supplied for the field application, and were independently tested using High Pressure Natural Gas Product at a nationally certified test facility in the USA. The provisional testing and a feasibility study was done on smaller diameter meters with water to demonstrate and prove the application at an international certified independent laboratory in the far east. A user in-field data set comparison will be shown between the bi-directional cone meters and the bidirectional ultrasonic meters used for the custody transfer measurement on the site. The resulting test and installation data demonstrates that the use of cone meters in a bi-directional configuration works well and is a real world cost effective alternative method to an old issue. The paper will not mention any trade names and will only use generic names and terminology




In order to prevent spam and automated file downloads for documents within the Measurement Library, please follow the instructions below and then you will be able to email a reference to this article.





Copyright © 2025