Title: Viscosity Effects On Small Propeller Current Meters
Author: Fumihide Takeda, Rikiya Takeda, Saburo Okada
Source: 1990 International Symposium on Fluid Flow Measurement
Year Published: 1990
Abstract: Small propeller current meters are adversely influenced by changes in the fluid viscosity of flow being metered. The reason and its corrective action are studied by using oil flow. The dynamic viscosity of flow being metered is changed from 0.944 to 23.93 g/cms The corrective action appears to be applied down to the viscosity of water flow, which is about 0.01 g/cms. These viscosity effects on the meters response to flow are given along with the mechanical friction effects around the meter shaft held by the meter housing.