Email Document Reference

Enter your email address below and the reference for this document will be sent to shortly from webmaster@ceesi.com.

Title: Development And Calibration Of The Boeing 18 kg/s (40 Ibm/sec) Airflow Calibration Transfer Standard
Author: Robert L. Stevens
Source: 1986 International Symposium on Fluid Flow Measurement
Year Published: 1986
Abstract: A high accuracy, flowmeter calibration transfer standard with an airflow range of 0.0182 (hereafter noted as 1.82E-02) to 18 kg/s (0.04 to 40 Ibm/sec) is described. The transfer standard contains 162 critical flow venturi meters that have a common discharge coefficient curve traceable through a Mass-Time calibration system to the U.S.A. National Bureau of Standards. The transfer standard venturi meters have a continuous curvature entrance and are designed to avoid boundary layer t r a n s i t i o n throughout their operating range. The venturi configuration is described and compared to the familiar circular arc configuration of Smith and Matz.(1) Data are presented which substantiate the method used to obtain a common operating curve. Calibration results from the Mass-Time System are presented and discussed. Discharge coefficient uncertainty is estimated to be 0.07% for individual meters and 0.05% for several meters operating in parallel.




In order to prevent spam and automated file downloads for documents within the Measurement Library, please follow the instructions below and then you will be able to email a reference to this article.





Copyright © 2025