Title: Numerical Simulation And Experiment On Averaging Pitot Tube With Flow Conditioning Wing
Author: Li-Jun Sun, Li-Xiao Qi, Tao Zhang
Source: Flomeko 2010
Year Published: 2010
Abstract: Cross-section of Averaging Pitot Tube (APT) flow sensor is a determinant factor in meter performance. In order to improve the performance of the APT flowmeter, three different cross-sections with Flow Conditioning Wing (FCW) were put forward. It was shown by Computational Fluid Dynamics (CFD) numerical simulation and prototype test that the performance of the FCW II cross-section, such as the linearity, the repeatability, and the value of differential pressure generated, is better than those of traditional circle and diamond cross sections