Title: Monitor R E G U L A T I On
Author: Ralph E. Boyd
Source: 1969 Western Gas Measurement Short Course
Year Published: 1969
Abstract: The word monitor comes to us from the Latin word monitus which means one that warns, or o v e r s e e . . The Gas Industryss usage applies to the second meaning, o v e r s e e .. The monitoring regulator is installed in s e r i e s with the primary regulator. In the event the primary regulator allows the system pressuee to r i s e above the set point of the monitor, the monitor will r e s t r i c t the flow and limit this pressuee r i s e. A working monitor must be pilot-loaded and must be installed upstream of the primary regulator. A non-working monitor may be installed either upstream or downstream of the primary regulator, and may be either spring or pilotloaded