Title: Flow Meter Calibration With Sonic Nozzles In Highpressure Natural Gas
Author: H. Dietrich, B. Nath, E. V. Lavante, m. Jaeschke, P. Schley, H.-J. Hotze
Source: Flomeko 2000
Year Published: 2000
Abstract: A new CEN-Standard for gas flow meters requires meters, which working at operating pressures of more than 4 bar to be calibrated accordingly. However in this pressure range, and especially for small flow rates, only a few suitable test rigs exist world-wide. Based on the good experience with sonic nozzles for air at atmospheric conditions, their use for the calibration of gas flow meters in high pressure natural gas is anticipated.




In order to prevent spam and automated file downloads for documents within the Measurement Library, please follow the instructions below and then you will be able to email a reference to this article.