Title: Compact Installation Testing Of A Hhr Propak Meter
Author: Adam Hawley Jacob Thorson Richard Wakeland
Source: 2015 International Symposium on Fluid Flow Measurement
Year Published: 2015
Abstract: Natural gas flow testing was conducted on a High Head Recovery (HHR) ProPak, a differential pressure meter manufactured by Flui dic Techniques (FTI) , at the Metering Research Facility (MRF) at Southwest Research Institute (SwRI) . The purpose of the testing was to determine the coefficient of discharge and the minimum upstream length required for various upstream and downstream piping disturbances. The test plan was designed based on the recommendations in American Petroleum Institute ( API ) Manual of Petroleum Measurement (MPMS) Chapter 22.2. The testing included meters of different beta ratios and line sizes, flow testing at different pressures and flow rates, and installation testing with various upstream and downstream disturbances. The results identified a compact installation that provided high meter performance while minimizing the overall footprint of the flow meter run




In order to prevent spam and automated file downloads for documents within the Measurement Library, please follow the instructions below and then you will be able to email a reference to this article.