Title: The Calibration, Proving And Validation Of Ultrasonic Flow Meters
Author: Klaus J. Zanker
Source: 2006 International Symposium on Fluid Flow Measurement
Year Published: 2006
Abstract: The gas industry has been spoiled by the Orifice Plate, which does not require flow calibration and the Dual Chamber Fitting, which allows field proving and validation. The USM construction and operation varies considerably, discouraging standardization and making flow calibration necessary. Liquid meters are commonly checked against volume provers, but they expect real time pulses, which are sometimes not available from the USM. Volume provers are difficult to use in gas flow, master metering offering a more practical approach. The USM produces an abundance of diagnostic data that could possibly be used to validate performance. These ideas are explored and developed further.